Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
Search Results "Pedestrian Traffic Control Button"
-
11B-411.2.1.5 Button requirements
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
-
R205 Alternate Pedestrian Access Routes (Section-by-Section Analysis)
R205 Alternate Pedestrian Access Routes (Section-by-Section Analysis) Alternate pedestrian access routes must be provided when a pedestrian circulation path is temporarily closed by construction...
-
R302 Pedestrian Access Routes (Section-by-Section Analysis)
R302 Pedestrian Access Routes (Section-by-Section Analysis)...
-
68.10(19) Pedestrian Access Route
(19) Pedestrian Access Route--A continuous and unobstructed path of travel provided for pedestrians with disabilities within or coinciding with a pedestrian circulation path....
-
Traffic Cones
[See subsections ...]
-
407.4.7.1 Buttons
407.4.7.1 Buttons. Car control buttons shall comply with 407.4.7.1....
-
Location: ADA Standard Section 407.2.1.4
Section 407.2.1.4 covers the current ADA Standards for the location of elevator call controls.
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow....
-
Controls
Controls Push buttons or plates and switches are subject to relevant requirements for controls and operating mechanisms, including the maximum 5 Ib operating force....
-
11B-407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction. Exception: Reserved....
-
11B-407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction. Exception: Reserved....
-
R303 Alternate Pedestrian Access Routes (See R205) (Section-by-Section Analysis)
R303 Alternate Pedestrian Access Routes (See R205) (Section-by-Section Analysis) In the 2005 draft of the proposed guidelines, the technical requirements for alternate pedestrian access...
-
407.4.7.1 Buttons
Car control buttons shall comply with 407.4.7.1....
-
407.4.7.1 Buttons
Car control buttons shall comply with 407.4.7.1....
-
Flush Controls: ADA Standard Section 604.6
Section 604.6 covers the current ADA Standards for water closets flush controls.
-
Elevator Car Controls: ADA Standard Section 407.4.6
Section 407.4.6 covers the current ADA Standards for the elevator car controls.
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated....
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
Height: ADA Standard Section 407.2.1.1
Section 407.2.1.1 covers the current ADA Standards for the height of the elevator call controls.
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable....
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1....