407.12.1 Vertical Reference Plane (Section-by-Section Analysis) This section proposes that the positioning of operable parts for side reaches and forward reaches be determined with respect...
Search Results "Forward Reach"
Commonly Searched Documents
-
407.12.1 Vertical Reference Plane (Section-by-Section Analysis)
-
Position: ADA Standard Section 305.5
Section 305.5 covers the current ADA Standards for the positioning of clear floor and ground space.
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADAS] 904.4.2 Forward Approach. ...
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADAS] 904.4.2 Forward Approach....
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADA Standards] 904.4.2 Forward Approach....
-
Issue 9: Reach (how far?)
Issue 9: Reach (how far?) APS devices can be located in landscaped areas if the pushbutton is reachable from a level paved area....
-
11B-308.4 Suggested reach ranges for children
These dimensions apply to either forward or side reaches. ...
-
407.8.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm)...
-
407.12.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm)...
-
Range or Cooktop: ADA Standard Section 804.6.4
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
§1193.41(f) Operable with limited reach and strength
(f) Operable with limited reach and strength. Provide at least one mode that is operable with user limited reach and strength....
-
Guidelines for Requirement 5
The proposed guidelines specified only the heights for forward reach, because those heights also are usable in side approach....
-
A4.2 Space Allowances and Reach Ranges
[See subsections ...]
-
A4.2 SPACE ALLOWANCES AND REACH RANGES
[See subsections ...]
-
Self Contained, Closed Products - Side Reach Range
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
4.34.3 Reach Ranges
[See subsections ...]
-
302.8 With Limited Reach and Strength (Section-by-Section Analysis)
302.8 With Limited Reach and Strength (Section-by-Section Analysis) In this section, the Board proposes to address the functional performance criterion for users with limited reach or...
-
Recessed Doors and Gates: ADA Standard Section 404.2.4.3
Section 404.2.4.3 covers the current ADA Standards for maneuvering clearances at recessed doors and gates.
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.
If the reach is over an obstruction (for example, an overhanging shelf) between 20 and 25 inches in depth, the maximum height is reduced to 44 inches for forward approach; or 46 inches for...