Section 302 covers the current ADA Standards for floor or ground surfaces.
Search Results "End Transfer Surface"
-
Floor or Ground Surfaces: ADA Standard Section 302
-
Transfer Sides (M301.2.3 and M302.2.3)
the surface, and that each transfer side provide unobstructed access to the transfer surface....
-
End-of-Row Stalls
End-of-Row Stalls The design of end-of-row stalls incorporates aisle space into the stall for easier maneuvering; consider this design even where a stall is not located at the end of...
-
Height: ADA Standard Section 1009.5.3
The height of the transfer platform shall comply with 1009.4.2....
-
M301.2.2 Transfer Surface Size
M301.2.2 Transfer Surface Size Subcommittee Recommendation: (Also agreed to by the full committee). A....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
Two Step Transfer Evaluation
The two-step transfers consisted of an adjacent transfer (no gap between two steps) and a ramped transfer over a constant 8 inch gap between two steps....
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
-
Floor or Ground Surfaces: ADA Standard Section 405.4
Section 405.4 covers the current ADA Standards for the floor or ground surfaces of ramps.
-
Transfer Steps
Transfer Steps Transfer steps are level surfaces in a composite structure that can be used for transferring from different levels to access play components....
-
Height: ADA Standard Section 1009.4.2
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
- Quadraplegic Transfer
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
Highest and Lowest Heights Obtained
These data represent the ability of the participants in the study to complete a transfer....
- Paraplegic Car Transfer Paraplegic Car Transfer Video
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long....
-