M305.2.1 Location
Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the...
-
M305.2.4 Cross Section
Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2.
-
M305.2.3 Height
During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed...
-
M305.2.6 Gripping Surface
Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of transfer support gripping surfaces...
-
M305.2.6 Gripping Surfaces (Section-by-Section Analysis)
The proposed rule did not provide any specific requirements regarding gripping surfaces on transfer supports. However, in the MDE NPRM preamble the Access Board repeatedly noted that...
-
M305.2.3 Height (Section-by-Section Analysis)
In the MDE NPRM there was no specific requirement regarding the height of the transfer support, only that it be “within reach” of the patient (proposed M305.2.1). The Access Board...
-
M305.2.4 Cross Section (Section-by-Section Analysis)
The proposed rule did not provide specific requirements for the cross section of transfer supports. However, in the MDE NPRM preamble, the Access Board noted that it was considering...
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302 Description: Transfer supports may contain elements to provide structural support or prevent...
-
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. Transfer supports should be required on both sides of the transfer surface and...
-
5.4.1 Transfer Support Location for M301 and M302
5.4.1 Transfer Support Location for M301 and M302 Description: Transfer supports assist individuals while making transfers on to the transfer area. Provisions require transfer...
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
5.4.5 Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and...
-
5.4.2 Transfer Support Length for M301 and M302
5.4.2 Transfer Support Length for M301 and M302 Description: Transfer support length applies to the gripping surface of the support, that portion of the support used to grasp or...
-
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surface cross section should comply with the...
-
5.3 Transfer Sides
5.3 Transfer Sides.
-
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer support should be a minimum length of 15 inches positioned so that...
-
5.3 Transfer Sides Recommendations
5.3 Transfer Sides Recommendations
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer gripping surface should be located within the minimum and maximum...
-
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The bottom of the transfer support shall have no...
-
Emergency Travel Safety Tips for Overnight Stays
Edition 1 – October 2017 By June Isaacson Kailes This document was made possible with support from: Grant to North Carolina Emergency Management from The North...
-
M305.2.1 Location
Transfer supports shall be located within reach of the transfer surface and shall not obstruct transfer onto or off of the surface when in position.
-
All Disabilities
All Disabilities Use proper language when referring to a person with a disability. For example, make reference to the person first, then the disability....
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302 Description: A clearance around the gripping surface is necessary to ensure sufficient space for...