alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these spaces where ramp...
Search Results "Ramp Slope"
Commonly Searched Documents
-
11B-808.3 Clear floor space
-
11B-808.3 Clear floor space
alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these spaces where ramp...
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
DETECTABLE WARNING
Curb ramps remove the needed cues for persons with visual impairments; detectable warnings have been developed as a replacement cue and warning to indicate the presence of a vehicular way...
-
210 and 504 Stairways
., where the accessible route is provided by an elevator, lift, or ramp)....
-
Background
Further, industry standards, specifications, and measurement procedures do not even address some measures important to facility usability in new construction, such as how to measure the slope...
- Rebuilding Together Anne Arundel County - Severna Park, MD
-
Location: ADA Standard Section 206.3
Section 206.3 covers scoping requirements in the most current ADA Standards for the required locations of accessible routes.
-
Elevated Play Components: ADA Standard Section 240.2.2
Section 240.2.2 covers scoping requirements in the current ADA Standards for elevated play components.
-
11B-206.2.6 Performance areas
Performance areas, including but not limited to, stages, platforms and orchestra pits, are treated as raised or lowered areas within a given story and all are required to be accessible by ramp...
-
b) Accessibility
For example, at the Kimball Playground, Margen's team used a very short level to measure slopes, notwithstanding Margen's assurance that his team always used a two-foot level....
-
Width of Spaces [1012.3]
Parking spaces at least 16 feet wide can accommodate vans equipped with a lift or ramp....
-
Keep Good Notes
If there isn’t an accessible entrance you’ll want to indicate how many steps there are and how much space is available to install a ramp or lift....
-
808.3 Clear Floor Space
alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these spaces where ramp...
-
Are public accommodations required to retrofit existing buildings by adding elevators?
A public accommodation generally would not be required to remove a barrier to physical access posed by a flight of steps, if removal would require extensive ramping or an elevator....
-
1130A.1 General
For the purpose of this section, “accessible routes” may include hallways, corridors and ramps....
-
1130A.1 General
For the purpose of this section, “accessible routes” may include hallways, corridors and ramps....
-
Accessible Route to Dumpster and Enclosure
For general understanding, site-specific information such as grading, slopes and cross-slopes are not included in a prototype design and thus, the design concept for all exterior elements...
-
Shooting Facilities
Fixed firing positions must have a 60-inch diameter space with slopes not steeper than 1:48 so a wheelchair user can turn around and have a level place from which to shoot....
-
Clear Deck Space
The slope of the clear deck space must not be greater than 1:48 (2%)....
-
1007.1 Accessible means of egress required
In assembly spaces with sloped floors, one accessible means of egress is required from a space where the common path of travel of the accessible route for access to the wheelchair spaces...