At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving picnic units with mobility...
Search Results "Pedestrian Elements"
-
F245.4.2.2 Routes Within Common Use and Public Use Areas
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
7 [§ 4.7.8]
If the curb ramp you are surveying is along a public right-of-way or at a pedestrian crossing, vehicles should be prohibited from parking directly in front of the curb ramp on the street...
-
Gangways
Gangways A gangway is a variable-sloped pedestrian walkway linking a fixed structure or land with a floating structure....
-
E2-a
Are pedestrian routes leading to or serving each service or activity area of the shelter free of objects that protrude from the side more than 4 inches into the route with the bottom of...
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
101.1 General
This document contains scoping and technical requirements for accessibility to sites, facilities, buildings, and elements by individuals with disabilities....
-
Private Funds Provided by Tenant
Based on the Exception, the path of travel elements and spaces under the landlord’s authority would not be subject to review or inspection....
-
205 Operable Parts
Mechanisms 205 Operable Parts 4.1.3(13) Controls and operating mechanisms in accessible spaces, along accessible routes, or as parts of accessible elements...
-
202.5 Alterations to Qualified Historic Buildings and Facilities
toilet facilities would threaten or destroy the historic significance of the building or facility, the exceptions for alterations to qualified historic buildings or facilities for that element...
-
205 Operable Parts
Clarification has been added that operable parts on accessible elements are required to comply as well, which is consistent with technical provisions for various types of covered elements...
-
202.4 Alterations Affecting Primary Function Areas
If elements of a path of travel at a subject building or facility that have been previously constructed or altered in accordance with the April 1, 1994 Texas Accessibility Standards (TAS...
- Seton Texas State ISA Parking Sign
-
§ 1194.21(l)
(l) When electronic forms are used, the form shall allow people using assistive technology to access the information, field elements, and functionality required for completion and submission...
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
-
Adaptability
The ability of certain building spaces and elements, such as kitchen counters, sinks, and grab bars, to be added or altered so as to accommodate the needs of individuals with or without...
-
Door Swing [§304.4] and Other Space Requirements
The turning space can overlap other space requirements, including clear floor space required at elements and fixtures....
-
§ 38.127(a)
(a) Sleeping compartments required to be accessible shall be designed so as to allow a person using a wheelchair or mobility aid to enter, maneuver within and approach and use each element...
-
Re: Single User Restroom Accessibility
Section 11B-202.3.2 indicates that "an alteration of an existing element, space, or area of a building or facility shall not impose a requirement for accessibility greater than new construction...
-
DEFINITION: MOBILITY DEVICES
All such devices must be permitted in any area that pedestrians use unless it would result in a fundamental alteration, is a direct threat, or creates a safety hazard....
-
R304.3.1 Turning Space
The 1.5 m (5.0 ft) dimension shall be provided in the direction of the pedestrian street crossing....
-
406.4.1 Clear height
The clear height of each floor level in vehicle and pedestrian traffic areas shall be not less than 7 feet (2134 mm). Advisory 406.4.1 Clear height. ...
-
R212.6 Benches
Benches that provide full back support and armrests to assist in sitting and standing are more usable by pedestrians with disabilities....