Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
Search Results "Transfer Surface Height"
-
11B-1008.4.2 Clear floor or ground space
- Pilot Rock ASW-20 Series Grill
-
1016.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to...
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for...
-
§ 38.159(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches (32 mm) and 11/2 inches (38 mm) or shall provide an equivalent grasping surface, and have eased edges with corner radii...
-
§ 38.29(b)
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
- GE® 30" Slide-In Electric Convection Range JS750EFES
-
§ 38.57(c)
(c) The diameter or width of the gripping surface of handrails and stanchions shall be 11/4 inches to 11/2 inches or provide an equivalent gripping surface and shall provide a minimum 11...
-
4.3.3 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
1002.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
1002.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
- GE® 30" Drop-In Electric Range JDS28DFWW
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
- Carr Corporation Folding Work Desk/Charting Stations
-
1018.10 Dune Crossings
The curbs or barriers shall prevent the passage of a 2 inch (50 mm) diameter sphere, where any portion of the sphere is within 2 inches (50 mm) of the crossing surface....
-
1018.10 Dune Crossings
The curbs or barriers shall prevent the passage of a 2 inch (50 mm) diameter sphere, where any portion of the sphere is within 2 inches (50 mm) of the crossing surface....
- GE Profile™ Series 30" Slide-In Double Oven Electric Convection Range PS950EFES
-
§ 38.75(c)