The slopes of beach access routes shall comply with 6.7.1 and 6.7.2
Search Results "Transfer Surface Height"
Commonly Searched Documents
-
6.7 Slope
-
1018.7 Slopes
The slopes of beach access routes shall comply with 1018.7.
-
1.2.5 Ramps
1.2.5 Ramps. When overall running slope and cross slope for accessible ramps are measured according to Sections 1.1.11 a recommended tolerance for these slopes is +0.5%. In the...
-
1016.8.3 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
Section 4.26.2
• Section 4.26.2 of the 1991 Standards requires handrail gripping surfaces to have a diameter of 1 ¼ inches to 1 ½ inches, or to provide an equivalent gripping surface....
-
Evaluation of transfers
Based on the guideline criteria in Table 13 pertaining to transfer heights alone (e.g. no gap and no obstacle), 15% of the sample could not transfer to a surface 24” high or higher and 57%...
-
1016.8.3 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1016.8.3 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
Features of an Accessible Examination Room
A clear floor space, 30” X 48” minimum, adjacent to the exam table and adjoining accessible route make it possible to do a side transfer. 2....
-
Assumptions
Assumptions Two industry standard specifications are used to determine the safety and accessibility of each surface: ASTM F1292‒99/04 Standard Specification for Impact Attenuation of...
-
T208.1 General
A passenger access route shall consist of a route complying with T208.2 between wheelchair spaces and doorways, walking surfaces complying with T302, and clearances complying with T504....
-
1.1.12 Ramp cross slope
A simple method of establishing the relative elevations of the top and bottom of each ramp is to use a rotating laser level on a tripod and document the difference in height on a stiff metal...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
Q9: Pavement Preservation Treatment Types
Q9: Several pavement preservation treatment types are not listed in the technical assistance. If the treatment type is not specifically on the list of maintenance treatments, is it...
-
4.6 Swimming Pools
There are at least 5 different ways to enter a pool that are accessible: you can use a lift, a sloped entry, a transfer wall, transfer steps, or accessible pool stairs. ...
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
- Figure 1009.5.7 Grab Bars – Drawing from the U.S. Access Board
-
607.4.2.1 Back Wall
607.4.2.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm)...
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim...
-
407.4.8.1.1 Size
Characters shall be ½ inch (13 mm) high minimum.
-
607.4.1.1 Back Wall
607.4.1.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm)...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum...