Types of boat slips are based on the size of the boat slips; whether single berths or double berths, shallow water or deep water, transient or longer-term lease, covered or uncovered; and...
Search Results "Double Door"
Commonly Searched Documents
-
11B-235.2.1 Dispersion
-
11B-809.7.1 Width
Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
- Muscular Dystrophy Association (MDA)
-
4.3.9 Doorway Design
For example, a 90 cm door is slightly smaller than a 91 cm door but is standard elsewhere in the world and would accommodate our entire sample....
-
3.1.4.1 Width of Non-RV Campsite Vehicle Parking Areas
Where a double camping unit is provided and two parking areas are provided to accommodate two vehicles side-by-side in an accessible parking spur, the total width of the vehicle parking...
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
1133B.2.4.2
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.2 Doors. 1133B.2.4 Floor level at doors. ...
- Living Earth Crafts Essex™ Pedicure Chair
-
M1
.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door and centered 60 inches above the floor?...
- Don-Jo Mfg., Inc. Door Viewers ULDV 180
- Don-Jo Mfg., Inc. Door Viewers DV 180
- Door King Inc. 6400 In-Ground Swing Gate Operator
- Don-Jo Mfg., Inc. Door Viewers DV 90
-
Temporary Solutions for Election Day: Accessible Entrance to Polling Place
Problem Four: Entrance door to the building is heavy and difficult to open. Suggestion: Keep the door propped open or station volunteers near the door to open it for voters....
-
11B-245.3 Accessible elements required
The accessible portion of the residence extends to those elements used to enter the commercial facility, including the front sidewalk, if any, the door or entryway, and hallways; and those...
-
1009.6.2 Stairway or elevator access
Exception: An interior area of refuge at the level of exit discharge that provides direct access to an exterior exit door....
-
KICK PLATE
An abrasion-resistant plate affixed to the bottom portion of a door to prevent a trap condition and protect its surface. Advisory Definition of KICK PLATE. ...
-
KICK PLATE
An abrasion-resistant plate affixed to the bottom portion of a door to prevent a trap condition and protect its surface. Advisory Definition of KICK PLATE....
-
KICK PLATE
An abrasion-resistant plate affixed to the bottom portion of a door to prevent a trap condition and protect its surface. Advisory Definition of KICK PLATE....
-
11B-705.2 Detectable directional texture
This surface will be placed directly behind the yellow detectable warning texture specified in Section 11B-705.1.2.1, aligning with all doors of the transit vehicles where passengers will...
- ASI Storage Solutions Phenolic Lockers
-
BHMA
ANSI/BHMA A156.10-1999 American National Standard for Power Operated Pedestrian Doors (see 404.3)....
-
EXIT
Exit components include exterior exit doors at the level of exit discharge, interior exit stairways and ramps, exit passageways, exterior exit stairways and ramps and horizontal exits....