The Euro-Urban Contour toilet is a classic European style toilet, available in an elongated style and can be mounted either on-the-floor or off-the-floor for ease of...
Search Results "Seating Space"
- Neo-Metro Euro-Urban Toilet Configured for In-Wall Flushing System
- Neo-Metro Contour Commercial Stainless Steel Toilet 8955 Series
-
T-turn Maneuvering Space
First, they stated that it was unclear when it is necessary for a designer to provide space for a T-turn....
-
T215 Communication Features
The scoping provisions for communication features address a number of different areas, including: signs or markers for priority seats, identification of wheelchair spaces and doorways that...
-
Are the ADA spaces ADA-only? Vans only in Van accessible spaces?
RESPONSE: Standard accessible and van accessible EVCS vehicle spaces which display the International Symbol of Accessibility (ISA), sometimes referred to as the wheelchair symbol, are generally...
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
§ 38.83(a)(1) General
complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas, each with a minimum clear floor space...
-
11B-221.2.1.2 Luxury boxes, club boxes, and suites in arenas, stadiums, and grandstands
In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with Section 11B-802.1 shall be provided in accordance with Table 11B-221.2.1.1...
-
1134A.8, Item 2
Floor space. A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
-
1134A.8, Item 2
Floor space. A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
-
A4.22.3 Clear Floor Space
Figure 28 (section 4.16) provides minimum clear floor space dimensions for toilets in accessible “unisex” toilet rooms....
-
Ticket Transfers and Secondary Ticket Market
Venues cannot require that accessible seats only be transferred to someone with a disability....
-
Exercise Machines and Equipment
Section 1004.1 of the 2010 Standards requires a clear floor space “positioned for transfer or for use by an individual seated in a wheelchair” to serve at least one of each type of exercise...
-
4.4.5 Slope
The slope of the clear floor or ground space for benches shall not exceed 1:48 (2 percent) in any direction. Exception....
-
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures Click here to view/download the pdf "1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures" (323...
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
4.34.5.4 BATHTUBS
If a bathtub is provided, then it shall have the following features:
-
Ticket transfer. (Section-by-Section Analysis)
The Department received many comments asking whether accessible seating has the same transfer rights as general seats....
-
We are also being asked to show the future space for the 1 Van accessible EV space that would be required in the future, if the equipment was installed. And due to the requirement for the access aisle beside this space, in the future it would be converted to an access aisle resulting in the loss of one parking space. As this project is right at the required number of parking spaces per zoning, it is not acceptable to the zoning reviewer to sign off on a plan that shows a “future access aisle for future EV van accessible charging space,” as they are approving the loss of a parking space, even though this would not happen until a future condition, upon which I assume there would be some review process for installation of EV charging equipment. What is the appropriate path forward in this situation?
RESPONSE: All work is required to comply with the applicable codes, standards and ordinances. Parking ordinances are typically adopted within each city and county in California....
-
12162(b)(2)(B)(ii)
(ii) space to fold and store a wheelchair; or...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching...
-
F221.2.1 Number and Location
Wheelchair spaces shall be provided complying with F221.2.1....
-
T602.2 Surfaces
Wheelchair space surfaces shall comply with T302....