At least 4 additional transfer positions located between the low and high transfer positions and separated by 1 inch (25 mm) minimum....
Search Results "Mobility Aid Seating Location"
Commonly Searched Documents
-
M302.2.1 Adjustability
- Figure 607.2 Clearance for Bathtubs – Drawing from the U.S. Access Board
- Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers – Drawing from the U.S. Access Board
-
Lift Compatibility (M301.4 and M302.4)
M301.4 and M302.4 would require diagnostic equipment used by patients in a supine, prone, or sidelying position, and diagnostic equipment used by patients in a seated position to be usable...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
- Domino Pro Listening System with Earbuds and Headphones (BE8005)
-
M302.4 Lift Compatibility
EXCEPTION: Where diagnostic equipment meets the requirements of M303 and provides a folding seat, the equipment shall not be required to comply with M302.4....
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
M305.2 Transfer Supports
Sub-Committee Recommendation: Transfer supports and their connections shall be capable of resisting vertical and horizontal forces of 250 pounds (1,112 N) applied at the worst case accessible location...
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1.
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum.
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair...
-
1. Transfer Surface
[See subsections ...]
-
5.8.2 Knee and Toe Clearance Under Breast Platform
5.8.2 Knee and Toe Clearance Under Breast Platform. The overall knee and toe space should be increased to a minimum of 28 inches deep, from the initially proposed 25 inch absolute...
-
F221.2.1.2 Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands
In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with 802.1 shall be provided in accordance with Table...
-
5.8.2.5 Toe Height
5.8.2.5 Toe Height. The toe height should be 18 inches minimum, measured above the ground when the top of the breast platform is 34 inches above the ground.
-
5.8.2.7 Base Support Allowance
5.8.2.7 Base Support Allowance. Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½...
-
5.8.2.2 Knee Clearance Depth at 27” Above the Ground
5.8.2.2 Knee Clearance Depth at 27” Above the Ground. The knee clearance should be increased at 27 inches above the ground to 18 inches minimum.
-
5.8.2.2 Knee Clearance Depth at 27” Above the Ground
5.8.2.2 Knee Clearance Depth at 27” Above the Ground The Committee recommends increasing the knee clearance at 27 inches above the ground to 18 inches minimum.
-
5.8.2.4 Unobstructed Floor Space
5.8.2.4 Unobstructed Floor Space. The unobstructed floor space in front of the base support should be a minimum of 17 inches deep.
-
5.8.3.1 Breast Platform Height
5.8.3.1 Breast Platform Height. The height of the top of the breast platform should be decreased to 26 inches above the floor. The upper height range for the breast platform was not...
-
5.8.2.8 Knee and Toe Clearance Recommendations Summary
5.8.2.8 Knee and Toe Clearance Recommendations Summary Ultimately, all of the knee and toe clearance recommendations in sections 5.8.2.1 – 5.8.2.7 are summarized below, in Figure...