The Committee used a 24-inch dividing point for table width to accommodate the dimensions for the maximum reach range....
Search Results "Maximum Dimension"
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
Turning Space: ADA Standard Section 809.2.2
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...
-
11B-404.2.3 Clear width
Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
-
11B-404.2.11 Vision lights
adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum...
-
11B-404.2.3 Clear width
Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
-
11B-404.2.11 Vision lights
adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum...
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls. Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. ...
-
Cross Slope
Comments indicated that specifications for cross slope (1:48 maximum) are not referenced in the curb ramp section. Response....
-
§382.133(a)
disability to use in the passenger cabin during air transportation an electronic assistive device specified in paragraph (c) of this section on all aircraft originally designed to have a maximum...
-
Width and Length
Width and Length Transfer walls must be a minimum of 12 inches wide to a maximum of 16 inches wide....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
239.2 Minimum Number
If a course is designed with the minimum 50 percent accessible holes, designers or operators are encouraged to select holes which provide for an equivalent experience to the maximum extent...
-
F239.2 Minimum Number
If a course is designed with the minimum 50 percent accessible holes, designers or operators are encouraged to select holes which provide for an equivalent experience to the maximum extent...
-
E. Key Reach Range
If there is key card controlled door hardware on building entrances, is the key card reader positioned so persons who use wheelchairs may approach and operate the opener (48" high maximum...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
5.3.3.2 Location Where Walls Provided
The centerline of the seat shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition. ...
-
4.7.5 Sides of Curb Ramps
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, it shall have flared sides; the maximum slope of the flare...
-
Scoping [4.1.3(5)]
access to: performing areas in assembly occupancies wheelchair seating locations in assembly occupancies incidental space or rooms not open to the public with a maximum...
-
4.1.6(4)(d)
(i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch side door stop....
-
5.3.3.2 Location Where Walls Provided
The centerline of the seat shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition....