Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
Search Results "Clear Floor Area"
-
11B-302.3 Openings
-
4.4.1* GENERAL
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
Car Controls [4.10.12]
Control panels must be located so that no floor button is higher than 54 inches for a side reach and 48 inches for a front approach....
-
F203.4 Raised Areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...
-
203.3 Raised Areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...
-
T210.4 Location
Wheelchair spaces shall be located as near as practicable to doorways that provide a means of accessible boarding and alighting.
-
T215.2.3 Doorways
Doorways that provide a means of accessible boarding and alighting shall be identified on the exterior of the non-rail vehicle by the International Symbol of Accessibility complying...
-
7(2)(b)(v)
The top of the fixture rim is a maximum height of 2'10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2'3" above the floor....
-
§ 38.53(a)(1)
(1) Passenger doorways on vehicle sides shall have clear openings at least 32 inches wide when open....
-
Residential Facilities: ADA Standard Section 203.8
Section 203.8 covers scoping requirements of general exceptions for residential facilities in the most current ADA Standards.
-
A4.10.12 CAR CONTROLS
In many cases, it will be possible to locate the highest control on elevator panels with 48 in (1220 mm) from the floor....
-
§ 38.53(d)(3) Exception
Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
A4.10.12 Car Controls
In many cases, it will be possible to locate the highest control on elevator panels within 48 in (1220 mm) from the floor....
-
Serving Counters
Serving Counters Where food or drinks are served at counters and the counter height is more than 34 inches above the floor, providing a lowered section of the serving counter at least...
-
302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10....
-
Approach, Enter, and Exit
Approach, Enter, and Exit Employee work areas are required by TAS 203.9 to be designed and constructed so that individuals with disabilities can approach, enter, and exit the work area...
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS NUMBER OF SEATS MINIMUM NUMBER OF REQUIRED WHEELCHAIR SPACES...
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS Number Of Seats Minimum Number Of Required Wheelchair Spaces 4 to 25 1...
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS NUMBER OF SEATS MINIMUM NUMBER OF REQUIRED WHEELCHAIR SPACES...
-
§ 38.53(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
11B-405.8 Handrails
[2010 ADAS] EXCEPTION: Within employee work areas, handrails shall not be required where ramps that are part of common use circulation paths are designed to permit the installation...
-
11B-405.8 Handrails
[2010 ADAS] EXCEPTION: Within employee work areas, handrails shall not be required where ramps that are part of common use circulation paths are designed to permit the installation of...