U.S. Access Board About Exemptions When a condition for an exception prohibits full compliance with a specific technical requirement on a section of trail as allowed in General...
Search Results "Emergency Transportable Housing Unit"
-
Documenting Exceptions and Notifying the U.S. Access Board About Exemptions
-
4.34.2(9)
(9) All controls in accessible spaces shall comply with 4.27. Those portions of heating, ventilating, and air conditioning equipment requiring regular, periodic maintenance and...
-
A4.34.6.1 CLEARANCE
The minimum clearances provide satisfactory maneuvering spaces for wheelchairs only if cabinets are removed at the sink.
-
A4.34.6.8 REFRIGERATOR/FREEZERS
Side-by-side refrigerator/freezers provide the most usable freezer compartments. Locating refrigerators so that their doors can swing back 180 degrees is more convenient for...
-
F244.2.3.2.2 Vehicles Other Than Recreational Vehicles
Where parking spaces are provided for vehicles other than recreational vehicles, at least one parking space shall comply with 1012.3, 1012.4, and 1012.5. Where more than one parking...
-
F245.2.5.2 Parking Spaces
Where provided, at least one parking space shall comply with 1012.3, 1012.4, and 1012.5. Where more than one parking space is provided, at least two parking spaces shall comply with...
-
F244.2.3.1 Outdoor Constructed Features
Where provided, at least one of each type of outdoor constructed features shall comply with 1011. Where more than one of the same type of outdoor constructed features is provided, at...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in...
-
1132A.4 Level floor or landing
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors with changes in height between...
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following:
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
11B-809.9 Kitchens
Kitchens shall be on an accessible route and shall comply with this section.
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in...
-
Residential Facilities [§208.2.3, §208.3.2]
Residential Facilities [§208.2.3, §208.3.2] Accessible parking at residential facilities is based on the ratio of parking spaces to dwelling units. ...
- Marx|Okubo Associates, Inc., Accessibility Group (ADA and FFHA)
-
382.101 What other boarding and deplaning assistance must carriers provide?
The only limitation on the means of providing this assistance is that hand-carrying by carrier personnel as defined in that section is prohibited, except in situations of an emergency evacuation...
-
608.3 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-809.11 Washing machines and clothes dryers
Where washing machines and clothes dryers are provided in residential dwelling units with adaptable features, one of each type shall be provided....
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
F245.2.3 Alterations and Additions
Where picnic units are altered or added, the requirements of F245.2 shall apply only to the picnic units that are altered or added until the number of picnic units with mobility features...
- Figure 608.5.1 Transfer Type Shower Compartment Control Location – Drawing from the U.S. Access Board