of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and other improved areas; parking access aisles; elevators...
Search Results "Elevator Exemption"
-
Sec.36.403(e)(2)
-
5.1.8 Slope
Exception: When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted where necessary for drainage. ...
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the...
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the...
-
GUARD OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
Swimming pools. (Section-by-Section Analysis)
Question 36: The Department would like to hear from public accommodations and individuals with disabilities about this exemption. ...
-
Swimming pools. (Section-by-Section Analysis)
In the NPRM, the Department also proposed at § 35.150(b)(5)(ii) that existing swimming pools with less than 300 linear feet of swimming pool wall be exempted from having to comply with the...
-
Mezzanine
Mezzanines have sufficient elevation that space for human occupancy can be provided on the floor below....
-
106.5.38 Mezzanine
Mezzanines have sufficient elevation that space for human occupancy can be provided on the floor below....
-
4.3.3 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
2.7 Tread Obstacles
Where the surface is paved or is elevated above the natural ground, obstacles shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. ...
-
4.3.3 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
Mezzanine
Mezzanines have sufficient elevation that space for human occupancy can be provided on the floor below....
-
11B-403.6 Handrails
Handrails provided in elevator cabs and platform lifts are not required to comply with the requirements for handrails on walking surfaces....
-
7.4.6 Tread Obstacles
Where the trail surface is paved or is elevated above the natural ground, tread obstacles shall not exceed ½ inch (13 mm) in height measured vertically to the highest point. ...
-
4.4.5 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
5.1.8 Slope
Exception: When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
11B-403.6 Handrails
Handrails provided in elevator cabs and platform lifts are not required to comply with the requirements for handrails on walking surfaces....
- Harmar RPL Residential Vertical Platform Lift
-
In-Flight Audio and Video Services
current rule, §382.47(b), only requires that U.S. carriers make safety briefings on the aircraft that are presented by video accessible to persons who are deaf or hard of hearing, and it exempts...
-
D.
of movie theaters across the country, including stadium-style movie theaters owned and/or operated by Cinemark, known as "stadium-style movie theaters," in which most of the seating is elevated...
-
3001.3 Accessibility
Passenger elevators and platform (wheelchair) lifts required to be accessible by Chapter 11A or 11B shall conform to Chapter 11A for applications listed in Section 108.2.1.2 regulated by...
-
Special Technical Provisions for Alterations to Existing Buildings and Facilities [4.1.6(3)]
Special provisions also address stairs, elevators, doors, toilet rooms, assembly areas, platform lifts, and dressing rooms....