The dot shall have a base diameter of 0.118 inch (3 mm) minimum and 0.120 inch (3.05 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
Search Results "Signage Height"
Commonly Searched Documents
- 
    
  
  11B-411.2.1.2.1 Keypads
  
 - 
    
  
  Examination Tables
  
Adjustable height treatment tables are available, but are not included in the sample. The MSRP for adjustable height treatment tables ranged from $1,500 to $2,400....
 - 
    
  
  11B-809.8 Doors
  
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than 1/2 inch (12.7 mm) of change in height between floor surfaces....
 - 
    
  
  5.8.2.7 Base Support Allowance Recommendation
  
To discuss the maximum base support height, the sub-committee looked at anthropomorphic data regarding footrest heights....
 - 
    
  
  605 Urinals
  
Section 604.5 provides criteria for accessible urinals, including the height and depth, clear floor space, and flush controls....
 - 
    
  
  703.5.7 Stroke Thickness
  
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
 - ThyssenKrupp Elevator Signa 4 Signal Fixtures
 - 
    
  
  Examination Tables and Chairs Subcommittee Report
  
Examination Tables and Chairs Subcommittee Report (including height position discussions as requested by full committee) May 28, 2013...
 - 
    
  
  11B-409.4.7.2 Operable parts
  
The telephone and emergency signaling device shall comply with Sections 11B-309.3 _|Operable Parts; Height|_ and 11B-309.4 _|Operation|_....
 - 
    
  
  A4.34.6.6 RANGES AND COOKTOPS
  
Although not required for minimum accessibility, countertop range units in a counter with adjustable heights can be an added convenience for wheelchair users....
 - 
    
  
  11B-409.4.7.2 Operable parts
  
The telephone and emergency signaling device shall comply with Sections 11B-309.3 _|Operable Parts; Height|_ and 11B-309.4 _|Operation|_....
 - 
    
  
  § 37.43(e)(2)(iii)
  
., relocation of phones to an accessible height, installation of amplification devices or TDDs);...
 - 
    
  
  11B-809.9.5 Lower shelving
  
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
 - 
    
  
  208.1.1
  
compliance would cause the barrier removal not to be readily achievable, a facility may provide parking spaces at alternative locations for persons who have disabilities and provide appropriate signage...
 - 
    
  
  General [9.1.1]
  
ADAAG requirements include specifications for protruding objects in 4.4 and for signage in 4.30....
 - 
    
  
  1009.11 Instructions
  
Signage shall comply with Chapter 11A, Section 1143A or Chapter 11B, Section 11B-703.5 requirements for visual characters. The instructions shall include all of the following: 1....
 - 
    
  
  11B-608.6 Shower spray unit and water
  
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
 - 
    
  
  703.6.1 Pictogram Field
  
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
 - 
    
  
  4.34.6.5(2)
  
(2) Rough-in plumbing shall be located to accept connections of supply and drain pipes for sinks mounted at the height of 28 in (710 mm)....
 - 
    
  
  1133A.5 Lower shelving
  
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
 - 
    
  
  1133A.5 Lower shelving
  
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
 - 
    
  
  Shower Spray Unit and Water: ADA Standard Section 607.6
  
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
 - 
    
  
  Toilet Compartments: ADA Standard Section 213.3.1
  
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
 - 
    
  
  11B-607.6 Shower spray unit and water
  
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....