Adjustable height treatment tables are available, but are not included in the sample. The MSRP for adjustable height treatment tables ranged from $1,500 to $2,400....
Search Results "Signage Height"
Commonly Searched Documents
-
Examination Tables
-
11B-809.8 Doors
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than 1/2 inch (12.7 mm) of change in height between floor surfaces....
-
5.8.2.7 Base Support Allowance Recommendation
To discuss the maximum base support height, the sub-committee looked at anthropomorphic data regarding footrest heights....
-
605 Urinals
Section 604.5 provides criteria for accessible urinals, including the height and depth, clear floor space, and flush controls....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
Examination Tables and Chairs Subcommittee Report
Examination Tables and Chairs Subcommittee Report (including height position discussions as requested by full committee) May 28, 2013...
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 _|Operable Parts; Height|_ and 11B-309.4 _|Operation|_....
-
A4.34.6.6 RANGES AND COOKTOPS
Although not required for minimum accessibility, countertop range units in a counter with adjustable heights can be an added convenience for wheelchair users....
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 _|Operable Parts; Height|_ and 11B-309.4 _|Operation|_....
-
§ 37.43(e)(2)(iii)
., relocation of phones to an accessible height, installation of amplification devices or TDDs);...
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
208.1.1
compliance would cause the barrier removal not to be readily achievable, a facility may provide parking spaces at alternative locations for persons who have disabilities and provide appropriate signage...
-
General [9.1.1]
ADAAG requirements include specifications for protruding objects in 4.4 and for signage in 4.30....
-
1009.11 Instructions
Signage shall comply with Chapter 11A, Section 1143A or Chapter 11B, Section 11B-703.5 requirements for visual characters. The instructions shall include all of the following: 1....
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
4.34.6.5(2)
(2) Rough-in plumbing shall be located to accept connections of supply and drain pipes for sinks mounted at the height of 28 in (710 mm)....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
- SLOPE Waste Receptacles