Search Results "LU/LA: Limited Use/Limited Application Elevator"
-
Record Retention
-
FAQ: Why should I enter keywords in the content I add to my Corada WorkSpace?
Loading this data into Corada allows it to be integrated with Corada’s existing database of other accessibility-related material, so users’ content will be in context with applicable federal...
-
11B-228.3.2 Minimum number
In public housing facilities, EVCS provided for common use of residents shall comply with Section 11B-228.3.2....
-
Machinery Spaces (§203.5)
Machinery Spaces (§203.5) Spaces used only by service personnel for maintenance, repair, or occasional monitoring of equipment Examples: elevator pits/ penthouses, mechanical/...
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section...
-
Sec.36.404(a)(2)
(2) For the purposes of this section, shopping center or shopping mall means --
-
§ 36.404(a)(2)
(2) For the purposes of this section, shopping center or shopping mall means –
-
407.2.1.6 Keypads
Where keypads are provided, keypads shall be in a standard telephone keypad arrangement and shall comply with 407.4.7.2.
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
409.4.7 Emergency Communications
Emergency two-way communication systems shall comply with 409.4.7.
-
1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (13 mm) under rated loading...
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2.
-
e-iv
e-iv. Are the highest floor control buttons mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? [ADA Standards § 4.10.12...