Visual contrast may be provided on the full surface of the curb ramp but should not extend to flared sides....
Search Results "Hinge Side Clearance"
Commonly Searched Documents
-
R305.1.3 Contrast
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
Transfer Platforms
ground level. 11 inches (280 mm) to 18 inches (455 mm) height of top surface Minimum 24 inches (610 mm) wide Minimum 14 inches (355 mm) deep Unobstructed side...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
Amusement Rides with Wheelchair Spaces
Amusement Rides with Wheelchair Spaces Minimum space requirements and clearances for wheelchairs are specified where a ride provides a wheelchair space....
-
Pedestrian Signal Phase Timing (Section-by-Section Analysis)
Pedestrian Signal Phase Timing (Section-by-Section Analysis) Pedestrian signal phase timing must comply with referenced MUTCD standards and use a pedestrian clearance time that is calculated...
-
Paperwork Reduction Act
This rule does not contain any paperwork or recordkeeping requirements and does not require clearance under the PRA....
-
Reading and Study Areas [8.2]
Recommendation: Specifications in 4.32, including clear passage for accessible routes, knee clearances and surface height (34 inch maximum) should be considered for movable furnishings as...
- Spectrum Industries Inc. Freedom XRS Elite Lectern™ Adjustable Height Lecterns
- Allegion Falcon SC70 Series Surface Mounted Door Control
- Pilot Rock FS-30 Campfire Ring
- Allegion Falcon SC80 Series Surface Mounted Door Control
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus. ...
-
Serving Counters
Lowered serving counter provides an accessible space to select and receive food items Notes on photo: Door under counter can be opened to provide required knee clearance when customers...
-
4.3.5.2 180-degree turn
4.3.5.2 180-degree turn Currently, the ADA-ABA does not have a specific clearance for this type of turn. The 1525 mm (60 in.) turning space would be used instead....
-
1009.5.2 Transfer Space
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
11B-410.7 Landing size
ETA Editor's Note There are no requirements for landing size in 2010 ADA Standards, although the door maneuvering clearance requirements at 404.2.4 should be applicable outside the platform...
- American Standard Madera 1.28 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System Side View
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet Side View
- American Standard Madera 1.6 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System Side View
-
Caroma® USA Sydney Low Profile 270 Easy Height Round Front Plus Toilet Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
ELKAY Filtered EZH2O® Bottle Filling Station with Integral Soft Sides® Fountain LZWS-EDFP217K Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
- Hill-Rom Golvo® 8000 / 8008 Patient Lift