Within three months of the effective date of this Agreement, the SDA will identify sources of qualified sign language and oral interpreters, real-time transcription services, and vendors...
Search Results "Floor-Level Exit Sign"
-
GENERAL EFFECTIVE COMMUNICATION PROVISIONS
-
T202 Accessible Means of Boarding and Alighting
Provision of accessible boarding and alighting may be accomplished through the use of ramps and bridgeplates, lifts, or level boarding and alighting systems that meet the technical requirements...
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
4. Assess During the Planning, Installation and Maintenance Phases
A 2 ft. digital level is most commonly used for accessibility assessments as it can measure greater variances within the cross slope than a longer level....
-
12.2 Q. What happens if a builder deliberately manipulates the grade so that a second story, which also might have been treated as a ground floor, requires steps?
Deliberate manipulation of the height of the finished floor level to avoid the requirements of the Fair Housing Act would serve as a basis for the Department to determine that there is reasonable...
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
Inclusive Safety Briefing
For example: Go down two flights and exit on the ground level, or You are on the ground level....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
-
305.7.1 Forward Approach
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove,...
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
Obstructions
Obstructions “Obstructions” are also prohibited by TAS 604.3.2 within the required water closet clearance. An obstruction is any element that violates the protruding object...
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
-
608.2.2.1 Clearance
608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION:...
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm). FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH
-
305.7.2 Parallel Approach
305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove,...
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches (610 mm).
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).