Search Results "Curb Ramp Surface"
- The Corada Shop
-
4.1.7(3)(a)
EXCEPTION: A ramp with a slope no greater than 1:6 for a run not to exceed 2 ft (610 mm) may be used as part of an accessible route to an entrance....
-
4.1.7(2)(a)
EXCEPTION: A ramp with a slope no greater than 1:6 for a run not to exceed 2 ft (610 mm) may be used as part of an accessible route at an entrance....
-
T202.1 General
Provision of accessible boarding and alighting shall be made through one or more of the following methods: ramps or bridgeplates complying with T402, lifts complying with T403, or a means...
-
1. Transfer Surface
[See subsections ...]
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4....
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4....
-
M302.2.3 Size
Transfer surfaces shall be 21 inches (610 mm) wide minimum and 17 inches (430 mm) deep minimum....
-
4.3.7 Slope
An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50....
-
4.3.7 SLOPE
An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50....
-
(3) the City's curb ramp design standard
(3) the City's curb ramp design standard utilized between 1994 and 2004 pursuant to which it constructed curb ramps with a V inch lip at the base in violation of federal disability access...
-
Step 3: Apply the Accessibility Provisions
This step involves looking at FSTAG, sections 7.4.1 through 7.4.8, which contain the technical requirements for trail grade, cross slope, resting interval, surface, clear tread width, passing...
-
Alterations/ Historic Preservation
Steeper slopes are allowed for short ramps where a 1:12 slope is not technically feasible....
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers....
-
5.1.4 Transfer Surface Height Measurement for M301 and M302
5.1.4 Transfer Surface Height Measurement for M301 and M302 The Committee recommends capturing the transfer surface height at the highest point of the seat in an uncompressed state, inclusive...
-
Boat Slips: ADA Standard Section 1003.2.1
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
ETA Questions: Interpretation of the "Changes in Level Are Not Permitted" Requirements
There are a number of places in the 2010 ADA Standards where the phrase "Changes in level are not permitted" occurs. However, the interpretation of this phrase is not clearly...
-
6.8.2 Grade and cross slope
Where the surface is paved or is elevated above the natural ground, the surface shall not be steeper than 1:48 (2 percent) in any direction....
-
1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with 1003.3. Advisory 1003.3 Clearances....
-
1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with 1003.3. Advisory 1003.3 Clearances....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....