Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
Search Results "Counter Height"
Commonly Searched Documents
-
11B-705.2 Detectable directional texture
-
214 and 611 Washing Machines and Clothes Dryers
An exception will permit the maximum height for the tops of these machines to be 2 inches higher than the general requirement for maximum high reach over an obstruction....
-
Section 5 References
Section 5 References i http://udeworld.com/analysis-of-seat-height-for-wheeled-mobility-devices ii ”The Impact of Transfer Setup on the Performance of Independent Transfers: Final...
-
11B-604 Water closets and toilet compartments
Section 408.5 and CBC Section 11B-608.9), and a threshold, between the shower receptor and the fixture clearance provided outside the shower (CBC Section 11B-608.2.2.1) with a maximum height...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a transition...
-
907.2.9 Group R-2
Exceptions: A fire alarm system is not required in buildings not over two stories in height where all dwelling units and contiguous attic and crawl spaces are separated from each...
-
Showers
Several commenters requested that the final Guidelines provide dimensions on the appropriate width and height of showers and shower doors....
-
11B-604.8.1.5 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped grab bar meeting the dimensional requirements of Sections 11B-604.5.1 and 11B-604.5.2 shall...
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Power Wheelchairs
The weight and bulk of a power wheelchair severely limits the size of obstacles-usually less than 50 mm (2 inches) in height-that can be negotiated without a ramp or bevel....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Other Sources
The Access Board used anthropometric data and other standards for the width of transfer surfaces on diagnostic equipment used by patients in a seated position (see M302.2.2), height of breast...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
When toilet and bathing facilities have doorway openings instead of doors, such as at airports or stadiums, the geometric identification symbol should be located at the proper height adjacent...
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
-
11B-805.4.3 Turning space
Treatment room - Treatment rooms are required to provide a turning space, accessible handwashing fixture, accessible counter and writing surface, and 36-inch wide access along the full length...
- Caroma® USA Caravelle Smart 270 One Piece Toilet
-
11B-604.3.2 Overlap
Section 408.5 and CBC Section 11B-608.9), and a threshold, between the shower receptor and the fixture clearance provided outside the shower (CBC Section 11B-608.2.2.1) with a maximum height...
- ViewPlus Technologies VP Cub Braille Printer
-
11B-805 Medical care and long-term care facilities
high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter...
-
11B-805.7 Built-in cabinets and work surfaces
Built-in cabinets, counters and work surfaces shall be accessible, including: patient wardrobes, nurse’s stations, administrative centers, reception desks, medicine preparation areas, laboratory...
- Hill-Rom Uno™ 102 Patient Lift
-
Introduction
Studies Average CV Mass-Weight 5.5‒20.4 7 11.1 14.1 −3.0 Stature-Sitting 2.9‒8.3 6 6.6 3.92 2.7 Shoulder Height...
-
11B-226.4 Baby changing tables
This has been generally understood to include the technical requirements for accessible routes, clear floor space, reach ranges, knee and toe space, worksurface heights, operable parts and...