Using Qualified Interpreters
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
(3) Usable bathrooms
The final Guidelines for usable bathrooms also provide that the usable bathroom specifications (either set of specifications) are applicable to powder rooms (i.e., a room with only a toilet...
-
15(d)
(d) Within the timeframe set forth in subparagraph 15(a), HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel has the required number of accessible rooms with...
-
4.1.4(1) GENERAL EXCEPTIONS
Accessibility is not required to elevator pits, elevator penthouses, mechanical rooms, piping or equipment catwalks, lookout galleries, electrical and telephone closets, and general utility...
- Access Board: Vertical Clearance for Protruding Objects
- Access Board: Tactile Sign Scoping
-
11B-604.8.1.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Installing grab bars in toilet stalls. 13. Rearranging toilet partitions to increase maneuvering space. 14. Insulating lavatory pipes under sinks to prevent burns. 15. ...
-
Performance Areas
Performance Areas An accessible route must connect stages and other performance areas directly to seating areas where they are directly connected by a circulation path as well as to dressing rooms...
-
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall.
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall....
- Figure 604.8.1.1 Size of Wheelchair Accessible Toilet Compartment – Drawing from the U.S. Access Board
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
M305.3.1.3 Vertical Position
The length of the gripping surface on vertical standing supports shall be 18 inches (455 mm) minimum.
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface.
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1.
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum.
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair...
-
5.8.2 Knee and Toe Clearance Under Breast Platform
5.8.2 Knee and Toe Clearance Under Breast Platform. The overall knee and toe space should be increased to a minimum of 28 inches deep, from the initially proposed 25 inch absolute...
-
5.8.2.5 Toe Height
5.8.2.5 Toe Height. The toe height should be 18 inches minimum, measured above the ground when the top of the breast platform is 34 inches above the ground.
-
5.8.2.7 Base Support Allowance
5.8.2.7 Base Support Allowance. Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½...
-
5.8.2.2 Knee Clearance Depth at 27” Above the Ground
5.8.2.2 Knee Clearance Depth at 27” Above the Ground. The knee clearance should be increased at 27 inches above the ground to 18 inches minimum.