The standard includes additional provisions for runway enclosures, electrical equipment and wiring, structural support, headroom clearance (which is 80 inches minimum), lower level access...
Search Results "Grab Bar Clearance"
-
F105.2.2 ASME
-
Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
[See subsections ...]
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
ACCESS AISLE
[DSA-AC] An accessible space adjacent to or between vehicle spaces that provides clearances in compliance with this code....
-
306.3.5 Width
Knee clearance shall be 30 inches (760 mm) wide minimum. Figure 306.3 Knee Clearance...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
- Activar Hiawatha 535/509/536/537 Solid 1 inch Diameter Pulls
- Willoughby Industries US-HC Cabinet Shower
-
General: ADA Standard Section 204.1
Section 204.1 of the ADA Standards covers information on scoping requirements for protruding objects in the most current ADA Standards.
-
Single-User Toilet Rooms: Split Plumbing
Note that lavatories (and other fixtures) cannot overlap door maneuvering clearances, including latch-side clearances....
-
TTY Shelf: ADA Standard Section 704.5
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
Background
Current accessibility standards include criteria related to seat height, clear floor space, and grab bar placement in places where transfers are expected [7]....
-
11B-902.1 General
Dining surfaces include, but are not limited to, bars, tables, lunch counters, and booths....
-
11B-404.3.5 Controls
Where push plates, vertical actuation bars or other similar operating devices are provided, they shall be placed in a conspicuous location....
-
11B-404.3.5 Controls
Where push plates, vertical actuation bars or other similar operating devices are provided, they shall be placed in a conspicuous location....
-
11B-902.1 General
Dining surfaces include, but are not limited to, bars, tables, lunch counters, and booths....
-
1. Abdomen depth (AD)
Univariate analysis The univariate analysis examines AD alone and is appropriate when no other clearance dimension is constrained or bounded (e.g., knee clearance height, foot clearance...
-
104 Conventions
When the requirement states a specified range, such as in section 609.4 where grab bars must be installed between 33 inches and 36 inches above the finished floor, that range provides an...