Exceptions: Two-way communication systems are not required at the landing serving each elevator or bank of elevators where the two-way communication system is provided within areas...
Search Results "Exception"
-
1009.8 Two-way communication
-
Turning Space: ADA Standard Section 809.2.2
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
1009.7.2 Separation
Exception: The fire-resistance rating and opening protectives are not required in the exterior wall where the building is equipped throughout with an automatic sprinkler system installed...
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Exceptions: 1. Residential dwelling units shall comply with Section 11B-233.3.4.2. 2....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Exceptions: 1. Residential dwelling units shall comply with Section 11B-233.3.4.2. 2....
-
11B-216.8 Toilet rooms and bathing rooms
Where clustered single user toilet rooms or bathing facilities are permitted to use exceptions to Section 11B-213.2, toilet rooms or bathing facilities complying with Section 11B-603 shall...
-
11B-216.8 Toilet rooms and bathing rooms
Where clustered single user toilet rooms or bathing facilities are permitted to use exceptions to Section 11B-213.2, toilet rooms or bathing facilities complying with Section 11B-603 shall...
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
F202.2.3.1 Existing Toilet Facility
EXCEPTION: Where only one toilet facility is provided in the existing building or facility, one toilet facility shall comply with F213.2 and F213.3 and shall serve the addition....
-
§ 36.404(a)
(a) This section does not require the installation of an elevator in an altered facility that is less than three stories or has less than 3,000 square feet per story except with respect...
-
11B-306.3.4 Clearance reduction
Exception: The knee clearance shall not be reduced at built-in dining and work surfaces required to be accessible by Section 11B-226.1....
-
Sec.36.404(a)
(a) This section does not require the installation of an elevator in an altered facility that is less than three stories or has less than 3,000 square feet per story, except with respect...
-
M305.2.1 Location
EXCEPTION: Where the support folds, collapses, or articulates, the transfer support shall be permitted to be located 3 inches (75 mm) maximum from the plane defined by the nearest edge of...
-
11B-612.2 Bench
Exception: A readily removable bench shall be permitted to obstruct the turning space required by Section 11B-612.3 and the clear floor or ground space required by Section 11B-903.2....
-
M301.4 Lift Compatibility
EXCEPTION: Where fixed overhead patient lifts are provided, and when their use with diagnostic equipment is permitted by an enforcing authority, diagnostic equipment shall not be required...
-
M302.4 Lift Compatibility
EXCEPTION: Where fixed overhead patient lifts are provided, and when their use with diagnostic equipment is permitted by an enforcing authority, diagnostic equipment shall not be required...
-
1013.1 General
EXCEPTION: When an entity determines that a condition in 1019 does not permit full compliance with a specific provision in 1013, the tent pad and tent platform shall comply with the provision...
-
3104.2 Separate structures
Exceptions: 1. Buildings on the same lot in accordance with Section 503.1.2 shall be considered a single structure. 2. ...
-
Urinals
Commenters urged that the exception be eliminated....
-
405.5 Clear Width
EXCEPTION: Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment provided...
-
F202.2.3.2 Existing Bathing Facility
EXCEPTION: Where only one bathing facility is provided in the existing building or facility, one bathing facility shall comply with F213.2 and F213.3 and shall serve the addition....
-
F206.2.6 Performance Areas
An accessible route shall be provided from performance areas to ancillary areas or facilities used by performers unless exempted by F206.2.3 Exceptions 1 through 6....
-
F242.4 Spas
EXCEPTION: Where spas are provided in a cluster, no more than 5 percent, but no fewer than one, spa in each cluster shall be required to comply with F242.4....