Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
Search Results "Exception"
-
11B-404.2.3 Clear width
-
1009.8 Two-way communication
Exceptions: Two-way communication systems are not required at the landing serving each elevator or bank of elevators where the two-way communication system is provided within areas...
-
1009.7.2 Separation
Exception: The fire-resistance rating and opening protectives are not required in the exterior wall where the building is equipped throughout with an automatic sprinkler system installed...
-
11B-404.2.3 Clear width
Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
-
Slope: ADA Standard Section 405.2
Section 405.2 covers the current ADA Standards for slope requirements on ramps.
-
1009.8 Two-way communication
Exceptions: Two-way communication systems are not required at the landing serving each elevator or bank of elevators where the two-way communication system is provided within areas...
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
Turning Space: ADA Standard Section 809.2.2
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
1009.7.2 Separation
Exception: The fire-resistance rating and opening protectives are not required in the exterior wall where the building is equipped throughout with an automatic sprinkler system installed...
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Exceptions: 1. Residential dwelling units shall comply with Section 11B-233.3.4.2. 2....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Exceptions: 1. Residential dwelling units shall comply with Section 11B-233.3.4.2. 2....
-
11B-216.8 Toilet rooms and bathing rooms
Where clustered single user toilet rooms or bathing facilities are permitted to use exceptions to Section 11B-213.2, toilet rooms or bathing facilities complying with Section 11B-603 shall...
-
11B-216.8 Toilet rooms and bathing rooms
Where clustered single user toilet rooms or bathing facilities are permitted to use exceptions to Section 11B-213.2, toilet rooms or bathing facilities complying with Section 11B-603 shall...
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
F202.2.3.1 Existing Toilet Facility
EXCEPTION: Where only one toilet facility is provided in the existing building or facility, one toilet facility shall comply with F213.2 and F213.3 and shall serve the addition....
-
§ 36.404(a)
(a) This section does not require the installation of an elevator in an altered facility that is less than three stories or has less than 3,000 square feet per story except with respect...
-
11B-306.3.4 Clearance reduction
Exception: The knee clearance shall not be reduced at built-in dining and work surfaces required to be accessible by Section 11B-226.1....
-
Sec.36.404(a)
(a) This section does not require the installation of an elevator in an altered facility that is less than three stories or has less than 3,000 square feet per story, except with respect...
-
M305.2.1 Location
EXCEPTION: Where the support folds, collapses, or articulates, the transfer support shall be permitted to be located 3 inches (75 mm) maximum from the plane defined by the nearest edge of...
-
11B-612.2 Bench
Exception: A readily removable bench shall be permitted to obstruct the turning space required by Section 11B-612.3 and the clear floor or ground space required by Section 11B-903.2....
-
M301.4 Lift Compatibility
EXCEPTION: Where fixed overhead patient lifts are provided, and when their use with diagnostic equipment is permitted by an enforcing authority, diagnostic equipment shall not be required...