The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
Search Results "Ramp Width"
Commonly Searched Documents
-
1009.6.2 Handrails
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
1016.8 Resting Intervals
This section contains the technical requirements for the length (1016.8.1), width (1016.8.2), and slope (1016.8.3) of resting intervals; and for a turning space (1016.8.4) where resting...
-
Openings [§302.3]
Openings [§302.3] Openings in ground and floor surfaces, such as grates, are limited in width to prevent passage of a ½” diameter sphere....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
§ 38.153(b)
(b) All step edges shall have a band of color(s) running the full width of the step which contrasts from the step tread and riser, either dark-on-light or light-on-dark....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry
Exceptions Considered for Wheelchair Spaces on Raised Platforms M303.2.2 Proposed Exception: The exception to the minimum width in M303.2.2 would apply where ramped surfaces are provided...
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
Section 2. Accessible route
Interior accessible routes may include corridors, floors, ramps, elevators and lifts. Exterior accessible routes may include parking access aisles, curb ramps, walks, ramps and lifts....
-
§100.201 Accessible route
Interior accessible routes may include corridors, floors, ramps, elevators, and lifts....
-
Technical Requirements [1017]
The technical requirements for trails include specific provisions for the surface, clear tread width, passing spaces, tread obstacles, openings, running slope, cross slope, resting intervals...
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
§ 38.107(b)
accessible shall be in close proximity to at least one seating location for persons using mobility aids and shall be connected to such a space by an unobstructed path having a minimum width...
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
a) Public Right-of-Way
., its system of sidewalks, curb ramps and crosswalks. 102....
-
Jean Tessmer
It is an excellent tool for laying out and placement of ADA routes, ramps, landings, random directional surfaces, and curb ramps. 1oo% compliance can be achieved when using the sliding...
-
1009.5.1 Transfer Platform
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. ...
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
§ 37.131(a)(1)(iii)
(iii) Outside the core service area, the entity may designate corridors with widths from three-fourths of a mile up to one and one half miles on each side of a fixed route, based on local...