Holds 5, 10, and 20 lb dry chemical extinguishers and features a large, sturdy base with molded-in handle for easy transport....
Search Results "Clearance Around Base"
Commonly Searched Documents
- Brooks Equipment FIRETECH™ Fire Extinguisher Stand
-
Courtroom Access
My question revolves around access to the Jury and Gallery spaces. ...
-
Other international standards
Australian NATSPEC Reference Volume 1: Building Works, Concrete Finishes Section Three classes of surface finish based on using a straightedge method of testing: Class A...
-
Trail Type
Water Trail: A trail that has a surface consisting predominantly of water (but may include land-based portages) and that is designed and managed to accommodate use on that surface....
-
Salsbury Industries See Through Metal Locker Six Tier Box Style Bridge 16 Box
Requires the Registered User plan or above. Login!
- American Safety Tread Co., Inc. Type T-24H Contrasting Stripe
-
§382.3 Expected maximum flight duration
Expected maximum flight duration means the carrier's best estimate of the total duration of the flight from departure gate to arrival gate, including taxi time to and from the terminals, based...
-
ADAPTABLE
As part of the initial design and construction, for example, structural backing would be provided for the later installation of grab bars, base cabinets under kitchen sinks would be removable...
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”. ...
-
C. Housing In Residential Postsecondary Vocational Education Centers
Recipients must extend housing opportunities without discrimination based on race, color, national origin, sex, or handicap....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Equivalent Facilitation
The Department, in consultation with the Access Board, has granted equivalent facilitation for a design similar to the ADAAG specification but having a dome base diameter of 1.325mrn and...
-
3.3 Finding of Unreasonable Hardship:
A finding of unreasonable hardship may be made by the enforcing agency and should be based upon a detailed project-specific analysis....
-
§ 38.159(c)(1) Design load
shall support a load of 600 pounds (2665 N), placed at the centroid of the ramp distributed over an area of 26 inches by 26 inches (660 mm by 660 mm), with a safety factor of at least 3 based...
-
Other Boxes: ADA Standard Section 221.2.1.3
Section 221.2.1.3 covers scoping requirements in the current ADA Standards for wheelchair spaces at other boxes not covered under 221.2.1.3.
-
11B-223.1.1 Alterations
In alterations and additions, the minimum required number is based on the total number of patient bedrooms or resident sleeping rooms altered or added instead of on the total number of patient...
- Magnuson Group FLAP Magazine & Literature Display
-
11B-604.5.1 Side wall
2013 CEC) requires a nurse call device at the side wall of a water closet that must be coordinated carefully with the side grab bar at an accessible water closet to ensure that accessible clearances...
- Aqua Creek Scout Excel
-
704.2.1 Clear Floor or Ground Space
The clear floor or ground space shall not be obstructed by bases, enclosures, or seats. Advisory 704.2.1 Clear Floor or Ground Space....
-
11B-704.2.1 Clear floor or ground space
The clear floor or ground space shall not be obstructed by bases, enclosures, or seats. [2010 ADAS] Advisory 704.2.1 Clear Floor or Ground Space. ...
-
1007.6.1 Size
Each area of refuge shall be sized to accommodate one wheelchair space of 30 inches by 48 inches (762 mm by 1219 mm) for each 200 occupants or portion thereof, based on the occupant load...
-
T402.2 Design Load
The factor of safety for ramps and bridgeplates shall be 3 or more, based on the ultimate strength of the material....