(iii) Costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY...
Search Results "Lavatory Height"
-
§ 36.403(f)(2)(iii)
-
M303.2.4.1 Toe Clearance
Toe clearance shall be provided at a height of 9 inches (230 mm) above the floor to a depth of 6 inches (150 mm) maximum....
-
§ 35.151(b)(4)(iii)(B)(3)
(3) Costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY...
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Appendix Two: Design Information and Accommodation Models
Research findings on Occupied Height Type of WhMD user Sam-ple Size Mean (SD) Min 5%ile 10%ile Me-dian 90%ile 95%ile Max...
-
§382.133(e)(2)
(2) The maximum weight and dimensions (length, width, height) of the device to be used by an individual that can be accommodated in the aircraft cabin consistent with FAA safety requirements...
-
4.34.5.2(2)
(2) The height of the water closet shall be at least 15 in (380 mm), and no more than 19 in (485 mm), measured to the top of the toilet seat....
-
308 Reach Ranges
In the final rule, the maximum side reach has been lowered to the height specified for forward reaches....
-
Base Support [No specific provision—affects M303.2.4]
To discuss the maximum base support height, the sub-committee looked at anthropomorphic data regarding footrest heights....
- Westside Center for Independent Living - Los Angeles, Santa Monica, CA
-
Obstacles [1018.5]
When beach access routes are constructed of concrete, asphalt, or boards, obstacles cannot exceed one-half inch in height at their highest point....
-
Data Deficiencies
Data Deficiencies Advocates on the committee, representing the interests of people with disabilities, strongly stated that a 17” height is essential to accommodate the largest segment...
-
11B-705.1.1.1 Dome size
warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and 0.47 inch (11.9 mm) maximum, and a height...
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
809.4 Toilet Facilities and Bathing Facilities
Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries....
-
809.4 Toilet Facilities and Bathing Facilities
Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries....
-
809.4 Toilet Facilities and Bathing Facilities
Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries....
-
9.2.2(6)
., one with a water closet, a lavatory, and a bathtub or shower). (f) if only half baths are provided, at least one half bath. (g) carports, garages or parking spaces....