Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
Search Results "Clear Tread Width"
-
11B-1003.3 Clearances
-
1002.4.4.2 Side Entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
1002.4.4.2 Side Entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
1002.4.4.2 Side Entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
Homemods.org
In some cases, modifying the home may also require repairs such as improved wiring to eliminate the need for dangerous extension cords or fixing loose stair treads....
-
R409.10 Handrail Extensions
In alterations where handrail extensions would reduce the clear width required for pedestrian access routes, handrail extensions shall not be required....
-
§ 38.31(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread or lift platform....
-
Overlap: ADA Standard Section 802.1.5
The term “circulation paths” used in Section 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
Station 1-Physical Characteristics
Tire or wheel width. Tire type (pneumatic, polyurethane, solid rubber, etc.)...
-
11B-802.1.5 Overlap
The term "circulation paths" used in Section 11B-802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
11B-802.1.5 Overlap
The term "circulation paths" used in Section 11B-802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
10.2.1(1)
(1) Where new bus stop pads are constructed at bus stops, bays or other areas where a lift or ramp is to be deployed, they shall have a firm, stable surface; a minimum clear length of 96...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
Areas of Rescue Assistance [4.1.3(9), 4.3.11]
Wheelchair spaces must be located outside required exit widths. The minimum 48 inch width, measured between the leading edge of handrails, provides clearance for assisted evacuation....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
§ 38.101(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate shall have, when the door is open, at least 2 footcandles of illumination measured on the step tread, ramp, bridge plate, or...
-
Passing Spaces (R302.4) (Section-by-Section Analysis)
Passing Spaces (R302.4) (Section-by-Section Analysis) Where the clear width of pedestrian access routes is less than 1.5 meters (5 feet), passing spaces must be provided at intervals...