§100.201 Exterior
Exterior means all areas of the premises outside of an individual dwelling unit.
-
R212.6 Benches
At least 50 percent, but no less than one, of benches at each location shall provide clear space complying with R404 adjacent to the bench....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
7.4.5.2 Slope
The cross slope of a passing space shall not exceed 1:20 (5 percent) in any direction....
-
Judicial Spaces: ADA Standard Section 206.7.4
Section 206.7.4 covers scoping requirements in the most current ADA Standards for accessible routes to judicial spaces.
-
208.2.3 Residential Facilities, F208.2.3 Residential Facilities
Parking spaces provided to serve facilities with residential dwelling units shall comply with 208.2.3....
-
Position: ADA Standard Section 703.3.2
Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text. Braille shall be separated 3/8 inch (9.5 mm) minimum...
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
Camp Shelters
One full, unobstructed side of the clear ground space must adjoin or overlap the trail or outdoor recreation access route (as applicable) or another clear ground space....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
-
305.7.1 Forward Approach
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove,...
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm). FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH