Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3....
Search Results "Toilet Building"
-
11B-809.5.1.1 Alarm appliances
-
TEMPORARY
[DSA-AC] Buildings and facilities intended for use at one location for not more than one year and seats intended for use at one location for not more than 90 days....
-
ENTRANCE
[HCD 1, HCD 2, HCD-1/AC and DSA-AC] Any access point to a building or portion of a building or facility used for the purpose of entering....
-
EMPLOYEE WORK AREA
Corridors, toilet rooms, kitchenettes and break rooms are not employee work areas....
-
4.34.5.2(1)
The water closet may be located with the clear area at either the right or left side of the toilet....
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
Employee Work Area
Corridors, toilet rooms, kitchenettes and break rooms are not employee work areas....
-
1115B.4.4.8, Item 1
SECTION 1115B BATHING AND TOILET FACILITIES (SANITARY FACILITIES) 1115B.4 Accessible fixtures. 1115B.4.4 Accessible showers. ...
-
a) Aquatic Program
Wood credibly opined that renovated pools have the features necessary to provide program access, namely: (1) an accessible route from the property line to the building; (2) an accessible...
-
Existing Site Constraints: ADA Standard Section 206.7.5
Section 206.5.1 covers scoping requirements in the most current ADA Standards for the use of platform lifts due to existing site constraints.
-
Wheelchair Transfer
The clear floor space requirements depend on how a person using a wheelchair can approach the toilet. Unlatching footrests allows a closer approach....
-
1028.5 Access to a public way
For other than Group E buildings, the area shall be located on the same lot not less than 50 feet (15 240 mm) away from the building requiring egress....
-
Dispersion: ADA Standard Section 225.3.1
Section 225.3.1 covers scoping requirements in the current ADA Standards for the dispersion of self service storage spaces.
-
ALTERATION
[DSA-AC] A change, addition or modification in construction, change in occupancy or use, or structural repair to an existing building or facility....
-
ALTERATION
[DSA-AC] A change, addition or modification in construction, change in occupancy or use, or structural repair to an existing building or facility....
-
Birthing Room Bath Tub Accessibility
11B-805.2.4 Toilet and Bathing Rooms....
-
6.1(3)
(3) Long term care facilities, nursing homes -- At least 50 percent of patient bedrooms and toilets, and all public use and common use areas are required to be designed and constructed to...
-
(1)(b)
(b) The height of the water closet should be 17 inches (430 mm) to 19 inches (485 mm) measured to the top of the toilet seat....
-
11B-206.7.5 Existing site constraints
While the site constraint must reflect exterior conditions, the lift can be installed in the interior of a building....
-
11B-206.7.5 Existing site constraints
While the site constraint must reflect exterior conditions, the lift can be installed in the interior of a building....
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge or where an accessible occupiable roof is above a story that is three or more...
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.
-
CHAPTER 10 MEANS OF EGRESS
ETA Editor's Note Sections from California Building Code Chapter 10 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....