New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
Search Results "Signage Height"
Commonly Searched Documents
-
§ 38.73(d)(2) Exception
-
Results comparison with current accessibility guidelines
Table 13 summarized the percentage of the subjects that could attain these heights for each protocol....
-
§ 38.95(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
§ 38.83(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
§ 38.125(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
Design Criteria for the Transfer Station
The station was designed to investigate the impact handhelds, back rests, heights, and seat widths have on transfer performance....
-
11B-809.10.7.3 Reinforcement for grab bars
The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. The backing shall 40 (sic) inches (1016 mm) minimum in length....
-
Section 4.1.2, Accessible Sites and Exterior Facilities: New Construction (Preamble, Section-by-Section Analysis)
Section 4.1.2, Accessible Sites and Exterior Facilities: New Construction This section addresses exterior features, elements, or spaces such as parking, portable toilets, and exterior signage...
-
Frederick Krimgold, Ph.D., Director, Disaster Risk Management Program, Virginia Tech Advanced Research Institute – National Capitol Region
Wayfinding and Signage (slides 5 - 10) Lighting. Size. Context. Contrast. Controls (slides 11 - 13) Timely Visibility. Position. Lighting....
-
CIRCULATION PATH
Whenever the accessible route diverges from the regular circulation path signage may be required to identify the departure from the regular route if not obvious.◼...
-
F. Assisted Listening Devices:
PSE shall also ensure that it provides the appropriate signage at entrances and ticket windows at The Palace, notifying patrons of the availability of the Assisted Listening Devices. ...
-
CIRCULATION PATH
Whenever the accessible route diverges from the regular circulation path signage may be required to identify the departure from the regular route if not obvious. ◼...
-
Alteration
resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height...
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
-
NOTES
See Analysis of Seat Heights for Wheeled Mobility Devices at: http://udeworld.com/analysis-of-seat-height-for-wheeled-mobility-devices. ...
-
4.34.6.4(1)
(1) The counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable or replaceable as...
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
The standards specify a maximum height (27”) for the leading edge of barriers so they are within cane sweep, but a minimum height is not specified....
-
Treads and Risers [4.9.2], Nosings [4.9.3]
Variation in riser height along a set of stairs can be a tripping hazard....
-
Carpet [§302.2]
The standards specify the maximum pile height (1/2” measured to the backing, cushion, or pad) and texture (level or textured loop, level cut pile, or level cut/uncut pile) and require firm...
-
Clear Floor or Ground Space
Clear Floor or Ground Space At least one clear floor or ground space (30 inches by 48 inches minimum) must be provided at each location that has a railing height of 34 inches maximum....
-
Transfer Steps
Transfer Steps The maximum height of transfer steps is 8 inches, although shorter heights are recommended....
-
Urinal Flush Controls
The proposed rule specified a maximum height of 44 inches (the maximum height for obstructed forward reaches)....
-
Section 4.1.2, Accessible Sites and Exterior Facilities: New Construction (Section-By-Section Analysis and Response to Comments)
New Construction (Section-By-Section Analysis and Response to Comments) This section addresses exterior features, elements, or spaces such as parking, portable toilets, and exterior signage...
-
Entry Points and Seats
When play components are located on an accessible route, the height required to transfer directly to the entry point or seat of a play component has a minimum of 11 inches (280 mm) and a...