A circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter, shall be located at entrances to women’s toilet and bathing facilities. The circle symbol shall contrast with the...
Search Results "TTY Signage"
Commonly Searched Documents
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
An equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward, shall be located at entrances to men’s toilet and bathing facilities....
-
7. Training Call Takers to Respond Effectively to TTY Calls
PSAPs should train their call takers to effectively recognize and process TTY calls. Providing appropriate equipment is only as effective as your staff training....
-
Detention and Correctional Facilities: ADA Standard Section 217.4.8
Section 217.4.8 covers scoping requirements in the current ADA Standards for TTYs in detention and correctional facilities.
-
11B-217.4.8 Detention and correctional facilities
In detention and correctional facilities, where at least one pay telephone is provided in a secured area used only by detainees or inmates and security personnel, at least one TTY shall...
- Takeform Fusion Signage Floor Directional Type B.2
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.1 Finish and contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
6. Maintenance and Back-up of TTY Equipment
maintain their accessible features and equipment in operable working condition.4 To comply with this regulation, PSAPs must implement procedures for maintenance and back-up capability for TTY...
-
11B-217.4.3 Building requirement
TTYs in public buildings shall be provided in accordance with Section 11B-217.4.3.1. TTYs in private buildings shall be provided in accordance with Section 11B-217.4.3.2. ...
-
704 Telephones
Section 704 provides technical criteria for telephones, including provisions for wheelchair access (704.2), volume control (704.3), and TTYs (704.4)....
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
Signage
Signage Common Problem: For permanent rooms and spaces, identification signage is mounted in the wrong location and cannot be read by persons who are blind or have low vision....
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5. Where pictograms are provided as...
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
Telecommunications. (Section-by-Section Analysis)
impairments--have been unable to use automated attendant systems because they are not compatible with TTYs or telecommunications relay services. ...
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
Signage [4.6.4]
Additional signage can clarify this, which may be important in lots with only one accessible space since that space must be a van space....
-
1007.10 Directional signage
1007.10 Directional signage. ...
-
Public Buildings: ADA Standard Section 217.4.3.1
Section 217.4.3.1 covers scoping requirements in the current ADA Standards for TTYs in public buildings.
-
11B-217.4.3.1 Public buildings
Where at least one public pay telephone is provided in a public building, at least one public TTY shall be provided in the building....