No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of Sections 11B-603 through 11B-610....
Search Results "Shower Drain"
Commonly Searched Documents
-
11B-806.2.4 Toilet and bathing facilities
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
4.21.3 Seat
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-608.5.1 Reserved
[2010 ADAS] 608.5.1 Transfer Type Shower Compartments....
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
-
Shower Spray Controls
Shower Spray Controls....
-
4. Faucet Controls
Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...
-
1134A.6 Showers
1134A.6 Showers. Showers required to be accessible shall comply with this section....
-
10. Shower Wand
Is there an adjustable height shower wand with at least a 60" long hose provided for persons who must shower from a seated position?...
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall.
-
11B-224.8.2 More than 50-bed facilities
When separate shower facilities are provided for men and women, at least one roll-in shower shall be provided for each group....
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls. ...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance. ...
-
1c
Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above?...
-
4.21.3 SEAT
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
1d
Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
-
4.8.1 General
Outdoor rinsing showers shall provide a hand-held shower spray unit complying with ABAAS section 608.6....
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....