608.5.1 Transfer Type Shower Compartments. In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38...
Search Results "Plumbing Element"
-
608.5.1 Transfer Type Shower Compartments
-
608.5.2 Standard Roll-In Type Shower Compartments
608.5.2 Standard Roll-In Type Shower Compartments. In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but...
-
608.5.3 Alternate Roll-In Type Shower Compartments
608.5.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar,...
-
ABA CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES
-
1133A.2, Item 4
4. The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space,...
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section.
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section. 1. Floor space and location. The minimum floor space provided at a water...
-
602 Drinking Fountains
-
604 Water Closets and Toilet Compartments
-
804.4 Sinks
Sinks shall comply with 606.
-
604.8 Toilet Compartments
Compartments containing more than one plumbing fixture shall comply with 603. Ambulatory accessible compartments shall comply with 604.8.2 and 604.8.3....
-
605 Urinals
-
Sinks [F212.3, Exception 2]
Sinks in camping and picnic facilities are not required to comply with the technical requirements for sinks in Section 606 of the ABA Standards, unless a cooktop or conventional...
-
III-7.5140 Drinking fountains
III−7.5140 Drinking fountains (ADAAG §4.1.3(10)). Where there is only one drinking fountain on a floor, it must be accessible both to individuals who use wheelchairs and to those who...
-
606 Lavatories and Sinks
-
606.1 General
Lavatories and sinks shall comply with 606. Advisory 606.1 General. If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. [ECTCR UFAS 4.34.5.3(2),...
-
806.2.4 Toilet and Bathing Facilities
At least one bathroom that is provided as part of a guest room shall comply with 603. No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with...
-
606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted where rough-in plumbing...
-
607 Bathtubs
-
607.1 General
Bathtubs shall comply with 607.
-
607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 30 inches (760 mm) wide minimum. A lavatory complying with 606 shall be permitted at the control...
-
608 Shower Compartments
-
608.1 General
Shower compartments shall comply with 608. Advisory 608.1 General. Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom...