Product Features 1 1/4" bar diameter. Set Screw Flange. Custom sizes available upon request. Peened safety grip. Product Specs Tubing: Fabricated of #18 ga...
Search Results "Overhead Handrail"
Commonly Searched Documents
- AJW Architectural Products UG20-Railing UG20X-Y108 108" Concealed Set Screw Flange, 1.25" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG130-Railing UG130X-Y108 108" Exposed Flange, 1.5" Diameter Grab Bar, Peened Grip - Configuration Y
- AJW Architectural Products UG3-Railing UG3X-Y108 108" Concealed Snap Flange, 1.5" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG120-Railing UG120X-Y108 108" Exposed Flange, 1.25" Diameter, Peened Grip - Configuration Y
-
T206 Handrails, Stanchions, and Handholds
The 2016 Non-Rail Vehicle Guidelines, as with the existing guidelines, require handrails, stanchions, or handholds to be provided at passenger doorways, fare collection devices (where such...
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. [2010 ADAS] Advisory 505.4 Height. ...
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 11B-505.4 Height....
-
Sections 505.10.2 and 505.10.3
Sections 505.10.2 and 505.10.3 of the 2010 Standards require handrail extensions at both the top and bottom of a flight of stairs....
-
Stairs
Error/Omission: Handrail extensions are not provided at the top and bottom risers....
-
4.9.4(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser....
-
Handrails, Grab Bars, and Tub and Shower Seats [4.26]
Handrails, Grab Bars, and Tub and Shower Seats [4.26] ADAAG 4.26 provides technical requirements for: handrails at ramps [4.8] and stairs [4.9] grab bars at water closets...
-
Section 4.9.4
• Section 4.9.4 of the 1991 Standards requires handrails at the bottom of stairs to continue to slope for a distance of the width of one tread beyond the bottom riser nosing and to further...
-
R409.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beyond the top and bottom of ramp runs....
-
R409.10.3 Bottom Extension at Stairways
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
R409.10.2 Top Extension at Stairways
At the top of a stair flight, handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beginning directly above the first riser nosing....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
4.9.4(7)
(7) Handrails shall not rotate within their fittings....