18″ long, 1 1/2″ wide Concealed mounting - mounting hardware included 3″ diameter flanges 1 1/2″ wall clearance Limited Faucet and Finish Warranty 1-1/2″ x 18″ ADA Grab...
Search Results "Grab Bars"
Commonly Searched Documents
- Delta 1-1/2″ x 18″ ADA Grab Bar, Concealed Mounting 40118-PS
- Delta 1-1/2″ x 36″ ADA Grab Bar Concealed Mounting 40136-PS
- Delta 1-1/2″ x 42″ ADA Grab Bar Concealed Mounting 40142-SS
- Moen Home Care Peened 42" Grab Bar
-
11B-609.2 Cross section
Grab bars shall have a cross section complying with Section 11B-609.2.1 or 11B-609.2.2....
-
Requirement 6 -- Reinforced Walls for Grab Bars
[See subsections ...]
- Seachrome Grab Bars
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-609.2.1 Circular cross section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
- Whitehall Mfg. 24" Grab Bar Flat Closure Plate
-
Grab bar clearance
Have local authorities accepted one-piece dispensers in toilet compartments that are recessed behind the horizontal grab bars? These units stick out ¼" or so....
-
11B-607.4.1 Bathtubs with permanent seats
For bathtubs with permanent seats, grab bars shall be provided in accordance with Section 11B-607.4.1....
-
11B-607.4.2 Bathtubs without permanent seats
For bathtubs without permanent seats, grab bars shall comply with Section 11B-607.4.2....
- Whitehall Mfg. 24" Grab Bar L-Shaped Closure Plate
-
11B-212.2 Kitchens, kitchenettes, and wet bars
Kitchens, kitchenettes and wet bars shall comply with Section 11B-804. [2010 ADA Standards] 212.2 Kitchens and Kitchenettes. Kitchens and kitchenettes shall comply with 804....
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
- Gamco Swing Up Grab Bar - 125-Swing-Up
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....