A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
Search Results "Exit"
-
907.2.2 Group B
-
1003.2.13.5.5 Identification
Where exit sign illumination is required by Section 1003.2.10.4, the area of refuge sign shall be illuminated....
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
Work Areas [4.1.1(3)]
Note that an accessible route through one work area ("research,") may be needed to provide access to an exit as part of an accessible means of egress....
-
1007.2 Continuity and components
1007.2 Continuity and components. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
-
1009.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
-
2. a. ii. Accessible entrance and exit route
[See subsections ...]
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
They must provide direct access to an exit stairway (or to an elevator equipped with standby power). Horizontal exits can substitute for areas of refuge....
-
1009.3 Stairways
Exit access stairways that connect levels in the same story are not permitted as part an accessible means of egress....
-
1009.3 Stairways
[DSA·AC & HCD 1.AC] In addition, exit stairways shall comply with Chapter 11A, Sections 1115A and 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
Character Proportions: ADA Standard Section 703.5.4
Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
-
Character Spacing: ADA Standard Section 703.5.8
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors shall comply with this section and Section 11B-809.8....
-
203 General Exceptions
Areas that are used only as work areas shall be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas....
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs. These types of signs are required to be tactile through the...
-
1007.6.2 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709. Each area of refuge shall be designed to minimize the intrusion...
-
1003.2.13.5.2 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709. Each area of refuge shall be designed to minimize the intrusion...
-
B. Braille Signs
B. Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision? [ADA Stds....
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with Sections 1009.4.1 and 1009.4.2.
-
Exception for accessible means of egress in existing buildings in IBC 2000
1003.2.13 Accessible means of egress. Accessible means of egress shall comply with Sections 1003.2.13.1 through 1003.2.13.7.1. Accessible spaces shall be provided with not less...