The following table provides guidance on reach ranges for children seated in wheelchairs. These dimensions apply to either forward or side reaches....
Search Results "Dimension Range"
Commonly Searched Documents
-
11B-1008.4.2 Clear floor or ground space
-
T505.3 Location of Operable Parts
Operable parts shall be located adjacent to the toe end of the clear space or shall be located no more than 10 inches (255 mm) measured from the centerline of the long dimension of the clear...
- Figure 308.2.2 Obstructed High Forward Reach – Drawing from the U.S. Access Board
- Figure 308.2.1 Unobstructed Forward Reach – Drawing from the U.S. Access Board
-
Reach Ranges
Reach Ranges. The 1991 Standards set the maximum height for side reach at 54 inches above the floor....
-
H13
H13. Is the operating control (switch, lever, button, or pull) of at least one of each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is...
-
I1a
I1a. For a side approach (clear floor space at least 30 inches long x 48 inches wide), is the coin slot no higher than 54 inches above the floor? [ADA Standards § 4.31.2, Fig. 44...
-
M14
M14. Is the operating control (switch, lever, button, or pull) for each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor...
-
8.4 Card Catalogs and Magazine Displays
Minimum clear aisle space at card catalogs and magazine displays shall comply with Fig. 55. Maximum reach height shall comply with 4.2, with a height of 48 in (1220 mm) preferred...
-
8.4 CARD CATALOGS
Minimum clear aisle space at card catalogs, magazine displays, or reference stacks shall comply with Fig. 55. Maximum reach height shall comply with 4.2, with a height of 48 in (1370...
-
A4.31.3 MOUNTING HEIGHT
In localities where the dial-tone first system is in operation, calls can be placed at a coin telephone through the operator without inserting coins. The operator button is located...
-
4.27.3* HEIGHT
The highest operable part of all controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
CASI California Survey Reports Acceptance Criteria - Construction and Manufacturing Tolerances AC 02-12
Dimensions that are not stated as "maximum" or "minimum" are absolute. 11B-104.1.1 Construction and Manufacturing Tolerances....
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm)...
-
1011.3 Operable Parts
technical requirements for the height of operable parts in 309.3 of the Architectural Barriers Act Accessibility Guidelines, which require operable parts to be placed within the reach ranges...
- Door King Inc. 1520/1524 Stand Alone Card Readers
-
T504 Fare Collection Devices
The Access Board believes such concerns are misplaced, and has not modified the specified height range for operable parts on fare collection devices (or any other devices)....
-
Accessible Routes Adjacent to the Playing Surface
Accessible Routes Adjacent to the Playing Surface If the accessible route is adjacent to the playing surface, it must not exceed 36 inches from any area where golf balls rest....
-
4.10.12(3)
(3) Height. All floor buttons shall be no higher than 54 in (1370 mm) above the finish floor for side approach and 48 in (1220 mm) for front approach. Emergency controls, including...
-
Clear Floor Space [4.25.2] and Height [4.25.3]
Clear Floor Space [4.25.2] and Height [4.25.3] Clear floor space for either a forward or side approach is allowed. However, since people who use wheelchairs may not be able to...
-
4.10.12(3)
(3) Height. All floor buttons shall be no higher than 48 in (1220 mm), unless there is a substantial increase in cost, in which case the maximum mounting height may be increased to...
-
4.25.3 Height
Accessible storage spaces shall be within at least one of the reach ranges specified in 4.2.5 and 4.2.6 (see Fig. 5 and Fig 6)....