A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
Search Results "Clear Floor Area"
-
11B-1002.5.1 Clear floor or ground space
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
407.2.1.3 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at call controls. Advisory 407.2.1.3 Clear Floor or Ground Space....
-
407.2.1.3 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at call controls. Advisory 407.2.1.3 Clear Floor or Ground Space....
-
Installation: ADA Standard Section 609.7
Section 609.7 covers the current ADA Standards for the installations of grab bars.
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
1005.4 Clear Floor or Ground Space
1005.4 Clear Floor or Ground Space....
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
Ground Level: ADA Standard Section 1008.2.4.1
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
Start of Play: ADA Standard Section 1007.3.1
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....