spaces shall be 108 inches (2743 mm) wide minimum and van parking spaces shall be 144 inches (3658 mm) wide minimum, shall be marked to define the width, and shall have an adjacent access aisle...
Search Results "Check-Out Aisle"
Commonly Searched Documents
-
11B-502.2 Vehicle spaces
-
B2
Does each accessible parking space have its own, or share, an adjacent access aisle that is least 60 inches (5 feet) wide? [ADA Standards § 4.6.3] Yes No...
-
1018.2 Aisles in assembly spaces
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
Parking Spaces [4.6.3]
Access aisles must be as long as the parking space....
-
11B-812.7 Access aisle
Access aisles shall adjoin an accessible route. Two vehicle spaces shall be permitted to share a common access aisle....
-
503.3.3 Marking
Access aisles shall be marked so as to discourage parking in them....
-
11B-802.4.2 Identification
Each designated aisle seat shall be identified by a sign or marker with the International Symbol of Accessibility complying with Section 11B-703.7.2.1....
-
Error/Omission: The built-up curb ramp projects into the access aisle.
Error/Omission: The built-up curb ramp projects into the access aisle. The accessible parking space and access aisle is not level in all directions....
-
Must the access aisle be flush with the pull-up space?
Yes, the access aisle at accessible passenger loading zones must be at the same level as the vehicle pull-up space it serves....
-
Location: ADA Standard Section 502.3.4
Section 502.3.4 covers the current ADA Standards for the required location of access aisles.
-
11B-502.3.4 Location
Access aisles shall not overlap the vehicular way....
-
502.3 Access Aisle
Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle....
-
502.3 Access Aisle
Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle....
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
502.3 Access Aisle
Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle....
-
Comparison of Single-User Toilet Room Layouts: Plan 3
An out-swinging door also minimizes the overall layout depth and cannot swing over the required clear floor space or clearance at any accessible plumbing fixture....
-
406.2.2 Clear height
The clear height of each floor level in vehicle and pedestrian traffic areas shall be not less than 7 feet (2134 mm). Canopies under which fuels are dispensed shall have a clear...
-
Parking and Passenger Loading Zones [4.6]
Accessible parking and passenger loading zones require aisles alongside parking and pull-up spaces so that persons using mobility aids can transfer and maneuver to and from vehicles....
-
Check-Out Aisles and Sales and Service Counters
Queues and waiting lines serving counters or check-out aisles, including those for food service, must be accessible to individuals with disabilities....
-
11B-502.3 Access aisle
Access aisles serving parking spaces shall comply with Section 11B-502.3. Access aisles shall adjoin an accessible route....
-
Closers
In addition, ADAAG requires that low-energy doors not open to back check faster than 3 seconds and require no more than 15 Ib, which is consistent with ANSI/BHMA A156.19....
-
G. Drop-off Area
If the lodging facility has covered passenger pickup/drop-off areas, does the pavement at such area(s), including the required 5' wide access aisle, slope 1:50 or less (critical dimension...