The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
Search Results "Wheelchair Space (Transportation)"
-
304.3.1 Circular Space
-
4.7.6 Water Hydrant Clear Floor or Ground Space
Clear floor or ground space around a water hydrant shall be 48 inches (1220 mm) by 72 inches (1830 mm) with the long side of the space adjoining an outdoor recreation access route, trail...
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
Clear floor space beside or between beds must be 36" wide
Remember that because the clear floor space required by 806.2.3 will be deeper than 24" to end up beside or between the beds where it will be usable, it will be in an alcove that is at least...
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
68.101(c)(5)(H) Element or space
(H) If an element or space of a lease is not specified in this subsection but is present in a state leasehold, that element or space shall comply with TAS 201.1....
- PUSHLiving
-
11B-604.8 Toilet compartments
Wheelchair accessible toilet compartments shall meet the requirements of Sections 11B-604.8.1 and 11B-604.8.3 _|Coat Hooks and Shelves|_....
-
Load and Unload Areas: ADA Standard Section 1002.3
A turning space complying with 304.2 and 304.3 shall be provided in load and unload areas....
-
36 CFR Part 1192 Americans with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles (2016 Non-Rail Vehicle Guidelines) - Preamble
ATBCB 2010-0004] RIN 3014-AA38 Americans with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles AGENCY: Architectural and Transportation Barriers Compliance...
-
Elements Not Addressed in Final Rule
The proposed rule included proposed scoping and technical requirements for recreational vehicle parking spaces in general parking areas at camping facilities....
-
Clear Floor Space [4.25.2] and Height [4.25.3]
Clear Floor Space [4.25.2] and Height [4.25.3] Clear floor space for either a forward or side approach is allowed....
-
J. Transfer Space
J. If there is a lavatory in the accessible stall, is there 42" between the center of the toilet and the near edge of the adjacent lavatory to permit persons with disabilities to...
-
Accessible Routes to Accessible Spaces and Elements [§206.2.4]
Accessible Routes to Accessible Spaces and Elements [§206.2.4] An accessible route must connect accessible facility entrances with all accessible spaces and elements in a facility that...
-
11B-1002.3 Load and unload areas
A turning space complying with Sections 11B-304.2 and 11B-304.3 shall be provided in load and unload areas....
-
11B-1002.3 Load and unload areas
A turning space complying with Sections 11B-304.2 and 11B-304.3 shall be provided in load and unload areas....
-
1002.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
1002.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
F206.4.4.2 Direct Connections
Direct connections to other facilities shall provide an accessible route complying with 404 from the point of connection to boarding platforms and all transportation system elements required...