11B-703.6.3 Text descriptors. Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2 _|Signs; Raised...
Search Results "Toilet Room Signage"
-
11B-703.6.3 Text descriptors
-
11B-703.2.2 Case
11B-703.2.2 Case. Characters shall be uppercase.
-
11B-703.7.2.3 Volume control telephones
11B-703.7.2.3 Volume control telephones. Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such...
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5 _|Signs; Visual Characters|_. Signs shall be clearly visible and within the sight...
-
11B-703.2.4 Character proportions
11B-703.2.4 Character proportions. Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of...
-
11B-703.2 Raised characters
11B-703.2 Raised characters. Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be...
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5. Signs shall be clearly visible and within the sight lines of standing and sitting...
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. Heights of low resolution...
-
11B-703.7.2.3 Volume control telephones
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be installed in accordance with...
-
11B-703.6.3 Text descriptors
Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
-
11B-703.2.2 Case
Characters shall be uppercase.
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-703.7.2.2 International Symbol of TTY
The International Symbol of TTY shall comply with Figure 11B-703.7.2.2.
-
The Presentation Area / Speaker’s Platform Design and Considerations
Both layouts incorporate presentation screens that are easily viewed from all areas of the room....
-
Technical Memorandum TM 2012-09 Employee Break Rooms
TM 2012-09 Employee Break Rooms Effective Date: January 22, 2013 2012 TAS Reference: 212 and 804 In accordance with TAS 106.5.28, kitchenettes and break rooms are not employee...
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
- Stop Signs and More Disabled Passenger Loading Zone Only Sign
- Hager Companies Plastic International Symbol 364M
- Hager Companies Plastic International Symbol 364L
- Hager Companies Plastic International Symbol 364S
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit?...
-
Sec.36.403(c)(2)
(2) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of or access...