Commonly Searched Documents
-
1134A.5, Item 1
-
III-5.4200 Professional office of a health care provider
ILLUSTRATION: A physician has offices on the first floor of a multistory building. The second floor has other types of offices. An elevator is not required....
-
Dining Surfaces and Work Surfaces for Children's Use: ADA Standard Section 902.4
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
Bank Requirement: ADA Standard Section 217.4.1
Section 217.4.1 covers scoping requirements in the current ADA Standards for TTYs provided at banks.
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
General Requirements of Part 382
Carriers shall accept as evidence that an animal is a service animal identifiers such as identification cards, other written documentation, presence of harnesses, tags or the credible verbal...
-
407.3.2 Alphabetic Keys (Section-by-Section Analysis)
The intent of this section is to address identification and orientation when alphabetic key entry is used....
-
Obligations of the Department
The survey instrument will include a requirement to include photographs and will also require the identification of appropriate remedial provisions, including the remedial provisions in...
-
Engineered Surfaces
Table 3: Engineered Surface Identification Surface ID: Roughness Index (in/ft): Crack Frequency (in): Crack Width (in):...
-
Communication Access at Doors [§806.3.2, §809.5.5]
They are more effective than locating a regular peephole at a lower height which can impact visual identification of visitors. ...
-
Mezzanine
An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the level or...
-
106.5.38 Mezzanine
An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the level or...
-
Turning Space: ADA Standard Section 809.2.2
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
11B-608.5.2 Standard roll-in type shower compartments
the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
Mezzanine
An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the level or...
-
e-vi
Are signs mounted on both sides of the elevator hoist way door opening (for each elevator and at each floor) that designate the floor with 2-inch minimum-height raised letters and Braille...
-
Story
That portion of a building included between the upper surface of a floor and upper surface of the floor or roof next above....
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...
-
Forward Approach: ADA Standard Section 904.4.2
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...