11B-809.10.5.1 Clear floor space
Cabinets under lavatories and toilets shall not encroach on the clear floor space....
-
Reservation Systems Requirements for Places of Lodging
the accessible features of the facility and the guest rooms....
-
2.1 General
ORARs shall connect the outdoor constructed features within each recreation site and shall connect to common use features such as toilets, showers, water spouts, trash or recycling receptacles...
-
9.3.2 Equivalent Facilitation
section, equivalent facilitation shall include the installation of electrical outlets (including outlets connected to a facility’s central alarm system) and telephone wiring in sleeping rooms...
-
Section 35.151(f) Housing at a Place of Education (Section-by-Section Analysis)
Some have double-occupancy rooms and a toilet and bathing room shared with a hallway of others, while some may have cluster, suite, or group arrangements where several rooms are located...
-
Toilets
Toilets:...
-
F224.1 General
Transient lodging facilities shall provide guest rooms in accordance with F224. Advisory F224.1 General....
-
Lavatory and Accessory Layout by Terry Salo, Architect, CASp
Lavatory and Accessory Layout by Terry Salo, Architect, CASp NOTE: The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper...
-
2010 ADA Standards - Plan Review Tool - Doors
2010 ADA Standards - Plan Review Tool - Doors Click here to view/download the pdf, Page 1 of 2 (258 KB) Click here to view/download the pdf, Page 2 of 2 (264 KB) * * * * * *...
-
California/ADA Plan Review Tool - Door Maneuvering Clearances
California/ADA Plan Review Tool - Door Maneuvering Clearances Click here to view/download the pdf "California/ADA Plan Review Tool - Door Maneuvering Clearances" (250 KB) * * *...
-
§ 36.406(d) Social service center establishments.
(d) Social service center establishments. Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping...
-
307.4 Vertical Clearance
307.4 Vertical Clearance. Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80...
-
307.4 Vertical Clearance
Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high. The...
-
Vertical clearance and protruding objects
• Entrances and aisles with adequate head clearance and minimal projections into the path of travel result in easier navigation for people with lessened visual acuity or those who...
-
307.4 Vertical Clearance
Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high. The...
-
1016.9 Protruding Objects
This section requires constructed elements on outdoor recreation access routes, resting intervals, and passing spaces to comply with the technical requirements for protruding objects...
-
Visual Notification Devices
Visual Notification Devices Care must be taken that notification devices intended to signal a door knock or bell are separately wired. Like auxiliary alarms, these devices can be...
-
9.2.2(4)
(4) If fixed or built-in storage facilities such as cabinets, shelves, closets, and drawers are provided in accessible spaces, at least one of each type provided shall contain...
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
The standards specify a maximum height (27”) for the leading edge of barriers so they are within cane sweep, but a minimum height is not specified. Curbs may be mistaken for a step...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.