The telephone cord shall be 29 inches (737 mm) long minimum.
Search Results "Elevator Car Door"
-
11B-409.4.7.4 Cord
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform. The 48 inch (1219 mm) long minimum dimension of the transfer...
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided.
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4.
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. Advisory 11B-1008.3.2.3 Transfer supports. Transfer supports are required on transfer platforms and transfer...
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform. The 48 inch (1219 mm) long minimum dimension of the transfer...
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided.
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4.
-
11B-409.4.7.4 Cord
The telephone cord shall be 29 inches (737 mm) long minimum.
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. Advisory 11B-1008.3.2.3 Transfer supports. Transfer supports are required on transfer platforms and transfer...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
5. Is a talk tube where two children talk to each other simultaneously considered one or two play components? If one end of the talk tube is at ground level and the other is on an elevated deck, is it considered a ground level or elevated play component?
If one end of the talk tube is at ground level and the other is on an elevated deck, is it considered a ground level or elevated play component?...
- AD Systems’ Exam Room Doors
-
Additional Number and Types: ADA Standard Section 240.2.1.2
Section 240.2.1.2 covers scoping requirements in the current ADA Standards for additional number and types of ground level play components.
-
11B-240.2.1.2 Additional number and types
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4....
-
11B-240.2.1.2 Additional number and types
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4....
-
11B-408.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....