Flush valves and related plumbing can be located behind walls or to the side of the toilet, or a toilet seat lid can be provided if plumbing fittings are directly behind the toilet seat....
Search Results "Transfer Wall"
Commonly Searched Documents
-
A4.16.5 Flush Controls
-
A4.23.3 Clear Floor Space
The alternate roll-in shower (Fig. 57b) also provides sufficient room for the “T-turn” and does not require plumbing to be on more than one wall....
-
Alterations [4.1.6(1), (2)]
Work broader in scope that may include such things as reconfiguration of walls and plumbed fixtures, generally requires full room access....
-
Plumbing/Restrooms
requirements at fixtures 11B-604 Compartment configuration side and end entry, toe clearances 11B-604 Side and rear wall...
-
A4.16.5 FLUSH CONTROLS
Flush valves and related plumbing can be located behind walls or to the side of the toilet, or a toilet seat lid can be provided if plumbing fittings are directly behind the toilet seat....
-
Clarification on Standard Roll-In Shower Compliance
Since there’s no maximum length for a side wall in a standard roll-in shower, do you think a pull-down grab bar would still be allowed?...
-
4.3.4 Knee and Toe Clearances
The forward-most point of the body or equipment touching a facing wall (Anterior-most point as reference); 2....
- Garaventa Evacu-Trac CD7 Evacuation Chair
-
Play Components
For the purpose of the guidelines, ramps, transfer systems, steps, decks, and roofs are not considered play components....
- Aquatic Access Pool Lift IGAT-180-AD
-
11B-805.7 Built-in cabinets and work surfaces
California, has issued Code Application Notice CAN 2-11B, dated 9/9/14, which includes the following interpretation of Section 11B-805.7: Built-in equipment consoles include recessed or wall...
-
Plan 4A: 13-Foot Wide Accessible Guest Room
at fixtures and turning space overlap (section 603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall...
-
21. New construction
Thus, if a doorway or wall is being altered, the door or other wall opening must be made wide enough to accommodate wheelchairs....
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 18 inches (457 mm) minimum from the water closet centerline where...
-
Pass Through Kitchen
In the final rule, this provision has been revised to more clearly address situations where counters, appliances, or cabinets are opposite a parallel wall....
-
Compartment Doors
The proposed rule specified the location of doors in the front partition, which were required to be hinged 4 inches from the side wall or partition farthest from the water closet (604.8.1.2...
-
609.4 Position of Grab Bars
The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1....
-
Detectable Warnings [4.29]
curb ramps, at areas where walking surfaces blend with vehicular ways without curb separation, railings, or other elements, and at the edges of reflecting pools not protected by railings, walls...
-
Single-User Toilet Rooms: Split Plumbing
Single-User Toilet Rooms: Split Plumbing Water closets and lavatories can be located on opposing walls....
-
Scoping [4.1.3(13)]
Scoping [4.1.3(13)] ADAAG covers elements that are fixed or built-in, including those bolted to floors or walls....
-
Den
Lamps wired to rocker wall switches Levers on all doors throughout the house FSC certified birdseye and quartersawn maple paneling Zoned heating on thermostats...
-
11B-812.8.7 Location
Signs may also be permanently posted on a wall at the interior end of the vehicle space....