In addition to the clear ground space for each wheelchair space, a clear ground space 36 inches wide must be provided on all usable sides of a table....
Search Results "Push Side"
Commonly Searched Documents
-
Picnic Tables [1011.2 and 1011.4]
-
Measures and Procedures
25.4-73.7 cm in 2.5 cm) with a fixed backrest 17” wide by 25” high (63.5x43.2 cm) and a 95° recline; a lateral grab bar (fixed height of 32” or 81.3 cm) and allows for attaching/detaching side...
-
Utilities at Recreation Sites
Provide a clear floor or ground space of at least 30 by 60 inches (760 by 1,525 millimeters) oriented for front or parallel approach to all usable sides of utilities, except at water hydrants...
-
1015.3 Height
Exceptions: For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, guards on the open sides of stairs shall have a height not less than 34...
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
- Hager Companies Plastic International Symbol 364L
- Takeform Fusion Signage Overheads Type C
-
8.6 Persons "Regarded As" Addicts and Illegal Drug Users
example: If an employer perceived someone to be addicted to illegal drugs based upon rumor and the groggy appearance of the individual, but the rumor was false and the appearance was a side-effect...
-
1009.5.7 Grab Bars
Grab bars shall comply with 609 and be located on at least one side of the transfer system. The grab bar located at the transfer platform shall not obstruct transfer....
-
11B-703.7.2.5 Cleaner Air Symbol
The symbol, which shall include the text “Cleaner Air” as shown, shall be displayed either as a negative or positive image within a square that is a minimum of 6 inches (152 mm) on each side...
-
704.4.1 Height
accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum permitted side...
-
Handrails Requirement
The Board has included provisions in section 505 that exempt walking surfaces from requirements for handrails on both sides and from requirements for handrail extensions....
-
Ambulatory Accessible Compartment
The width of ambulatory compartments is specified to ensure that the grab bars required on both sides are simultaneously within reach....
-
604.7 Dispensers
If toilet paper dispensers are installed above the side wall grab bar, the outlet of the toilet paper dispenser must be 48 inches (1220 mm) maximum above the finish floor and the top of...
-
704.4.1 Height
accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum permitted side...
-
R309.4 Curb Ramps or Blended Transitions
At parallel parking spaces, curb ramps and blended transitions should be located so that a van side-lift or ramp can be deployed to the sidewalk and the vehicle occupant can transfer to...
-
T702.4 Character Height
Table T702.4—Character Height Sign location Minimum character height Exterior route or destination signs on boarding side of non-rail...
-
704.4.1 Height
accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum permitted side...
-
407.12.3 Forward Reach (Section-by-Section Analysis)
) would thus be new to the existing 508 Standards, it nonetheless would provide greater design flexibility by permitting controls to be configured for forward reach (or, alternatively, side...
-
A4.1.3(19)(a)
For example, a marker which contrasts (light on dark or dark on light) and which also reflects light could be placed on the side of such seating so as to be visible in a lighted auditorium...
-
Obstructions [4.7.8]
Where space at the top is less than 48 inches, side flares must have a maximum slope of 1:12 instead of 1:10 at the curb face....
-
Grab Bars [4.20.4] and Controls [4.20.5]
Seats at the head of the tub are limited to a 15 inch depth so that back support is available from the side wall (which is why grab bars cannot be placed on the seat wall)....