Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
Search Results "Clear"
Commonly Searched Documents
-
306.3.3 Minimum Required Depth
-
4.4.2 Head Room
Walks, halls, corridors, passageways, aisles, or other circulation spaces shall have 80 in (2030 mm) minimum clear head room (see Fig. 8(a))....
-
4.4.2 HEAD ROOM
Walks, halls, corridors, passageways, aisles, or other circulation spaces shall have 80 in (2030 mm) minimum clear head room (see Fig. 8(a))....
-
R409.10 Handrail Extensions
In alterations where handrail extensions would reduce the clear width required for pedestrian access routes, handrail extensions shall not be required....
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
Where the reach depth to the operable parts of all controls as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
- Accessible Icon Project
- ADDitude Online Magazine
-
Fixed Seating and Tables
An accessible route provides access to each accessible table and a clear floor area 30 inches by 48 inches is provided at each accessible seating location....
-
National Network of ADA Centers
In Section 5.1, pages 66 and 69, justifications for a higher transfer height is made at 25” and chapter 6 (page 139) a more clear discloser is given for a high height number and the exclusion...
- Stop Signs and More Disabled Passenger Loading Zone Only Sign
- Rockwood Manufacturing Company 603 Door Guard - Cast Aluminum
- Magnuson Group VALUTA Waste Receptacles
-
11B-504.4.1 Contrasting stripe
Interior stairs shall have the upper approach and lower tread marked by a stripe providing clear visual contrast....
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
10. Can a transfer platform be an irregular shape as long as it incorporates the minimum rectangle of 14 by 24 inches?
It is recommended that the clear edge provided for transfer be a straight edge. The 24 inch side of the transfer platform must be free from obstructions to allow a person to transfer....
-
Slope [1013.3]
When the surface of tent pads, tent platforms, and clear ground spaces is constructed of materials other than asphalt, concrete, or boards, the surface must be no steeper than 1:48 (2 percent...
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
H. Door Maneuvering Clearance
.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor space on the latch side for persons...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
B4
[ADA Standards § 4.6.5] Yes No If No: Can the route be cleared by removing or raising low objects, or can each van accessible parking space be relocated?...
-
1134A.8, Item 4.3
The clear floor space required by Item 2 shall not extend into the knee and toe space more than 19 inches (483 mm). (See Figure 11A-9D)....
-
4.13.6 Maneuvering Clearances at Doors
The floor or ground area within the required clearances shall be level and clear....
-
Side Approach
Recommendation: The clear floor space should be centered on the ATM unit....