5.3.2 Transfer Sides Recommendations for M301 Description: The transfer side provision requires the transfer surface to be located to provide options to transfer onto the short side and...
Search Results "Signage Location"
Commonly Searched Documents
-
5.3.2 Transfer Sides Recommendations for M301
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
- Magnuson Group VESUVIO Ash Trays
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement can be...
-
Toilet Paper Dispensers
measured to the centerline of the dispenser.The paper outlet of the dispenser must be located 15 inches minimum and 48 inches maximum above the finish floor....
-
11B-608.5.2 Standard roll-in type shower compartments
and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located...
-
3.5 Gahanna Stoneridge Plaza Movies 16, 323 Stoneridge Lane, Gahanna, Ohio
Stoneridge Plaza Movies 16, 323 Stoneridge Lane, Gahanna, Ohio - In Auditorium 3, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium from their current location...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
- Durateq® Stadium Captioning
-
11B-1009.3.2 Submerged depth
Where landings are required by Section 11B-405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-217.4.1 Bank requirement
[2010 ADA Standards] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Control buttons shall be located no higher than 48 inches (1219 mm) above the ground surface adjacent to the pole....
-
11B-707.5.2 Receipts
Exceptions: Machine location, date and time of transaction, customer account number, and the machine identifier shall not be required to be audible....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
11B-221.1 General
Companion seats are required next to each wheelchair seating location. The companion seat is a conventional seat that accommodates a friend or companion....
-
11B-206.2.8 Employee work areas
Common use circulation paths located within employee work areas that are less than 1000 square feet (93 m2) and defined by permanently installed partitions, counters, casework, or furnishings...
-
IV. RESOLVING ADA COMPLAINTS THROUGH MEDIATION
The town created a van-accessible parking space with required access aisle and signage, installed curb cuts at the accessible parking space and near the main gate entrance, and leveled the...